CD3 FITC / CD19 PE / CD45 Cy5-PE[CD3 / CD19 PE / CD45 Cy5]
-
Catalog number
MBS396670
-
Price
Please ask
-
Size
NA
-
-
Products_type
Antibody
-
Reactivity
Human
-
Properties
Cy5 antibodies are excited by the 650-nanometer wave of an argon laser and detected at a 670-nanometer captor. This MyBioSource Fluorescein isothiocyanate (FITC) antibody is currently after some BD antibodies the most commonly used fluorescent dye for FACS. When excited at 488 nanometers, FITC has a green emission that's usually collected at 530 nanometers, the FL1 detector of a FACSCalibur or FACScan. FITC has a high quantum yield (efficiency of energy transfer from absorption to emission fluorescence) and approximately half of the absorbed photons are emitted as fluorescent light. For fluorescent microscopy applications, the 1 FITC is seldom used as it photo bleaches rather quickly though in flow cytometry applications, its photo bleaching effects are not observed due to a very brief interaction at the laser intercept. MyBioSource FITC is highly sensitive to pH extremes.
-
Conjugation
Cy5.5, Anti-FITC Antibody
-
Gene target
-
Gene symbol
CD19, PTPRCAP, PTPRC
-
Short name
CD3 FITC / CD19 PE / CD45 -PE[CD3 / CD19 PE / CD45 ]
-
Technique
FITC, Fluorescein
-
Host
Mouse
-
Label
FITC
-
Alternative name
CD3 fluorecein / CD19 molecule peroxidase / CD45 cyanine 5-peroxidase[CD3 / CD19 molecule peroxidase / CD45 cyanine 5]
-
Alternative technique
fluorescine
-
Alternative to gene target
CD19 molecule, B4 and CVID3, CD19 and IDBG-23791 and ENSG00000177455 and 930, protein binding, Cell surfaces, Cd19 and IDBG-209475 and ENSMUSG00000030724 and 12478, CD19 and IDBG-638894 and ENSBTAG00000032122 and
-
Gene info
-
Identity
-
Gene
-
Long gene name
CD19 molecule
-
Synonyms gene name
-
Locus
-
Discovery year
1991-06-04
-
Entrez gene record
-
Classification
- CD molecules
- Immunoglobulin like domain containing
- Minor histocompatibility antigens
-
VEGA ID
-
Locus Specific Databases
Gene info
Gene info
MeSH Data
-
Name
-
Concept
Scope note:
The number of CD4-POSITIVE T-LYMPHOCYTES per unit volume of BLOOD. Determination requires the use of a fluorescence-activated flow cytometer.
-
Tree numbers
- E01.370.225.500.195.107.595.500.150
- E01.370.225.625.107.595.500.150
- E05.200.500.195.107.595.500.150
- E05.200.625.107.595.500.150
- E05.242.195.107.595.500.150
-
Qualifiers
ethics, trends, veterinary, history, classification, economics, instrumentation, methods, standards, statistics & numerical data
Similar products