Products for Research Use Only

MICROVUETMC4a EIA

CAT: 1008-A035Size: 96 wells/testDry Ice: NoHazardous: No
Product image 1
1 / 1
CAT#:1008-A035Size:96 wells/test
Selected
24/48H Stock Items & 2 to 6 Weeks non Stock Items.
Quick Request Actions
Background
Under normal conditions, activation of the classical or lectin complement pathways results in the cleavage of the complement protein, C4 into C4a and C4b by the protease, C1s. C4a is rapidly cleaved to its more stable, less active form C4a-des Arg form by endogenous serum carboxypeptidase N enzyme. Thus, quantitation of C4a-des Arg should provide a reliable measurement of classical or lectin complement pathway activation that has occurred in test samples. The MICROVUE C4a assay, a rapid, highly specific and quantitative procedure for measuring C4a levels, is designed for investigations into the role or status of complement pathway activation in numerous research settings, and for monitoring the generation of C4a in vivo or in vitro. C4a is the weakest of the anaphylatoxins, compared with C3a and C5a, however, it does play a role in bringing about vascular permeability changes, the induction of smooth muscle contraction and the release of histamine from mast cells and basophils. C4a is believed to play a role in several autoimmune diseases including rheumatoid arthritis, SLE and acute glomerulonephritis. It has recently been implicated as a marker for both acute and chronic Lyme disease.
Description
The MICROVUE C4a Enzyme Immunoassay is for the measurement of C4a in human or primate serum, plasma, and other biological or experimental samples.
Cross Reactivity
African Green Monkey, Cynomolgous monkey, Rhesus monkey
Assay Performance Time
2.5 hours
Standard
5
Sample Type
Serum/EDTA Plasma 10 μL
Sample Volume
Serum 20.9–4437.2 ng/mL, EDTA Plasma 383.5–8168.2 ng/mL
Limit Of Detection
0.29 ng/mL
Form
96 well plate with 12 eight-well strips in a resealable foil pouch
Storage Conditions
Store the unopened kit at 2°C to 8°C. Refer to Product Insert for additional storage details.
Limit Of Quantification
61 ng/mL
Controls
2
Inter Assay
4.0–4.4%
Intra Assay
3.7–4.3%