Interference Test Kit EXTRA
CAT:
952-K2010008
Size:
1 Each
Price:
Ask
- Availability: 24/48H Stock Items & 2 to 6 Weeks non Stock Items.
- Dry Ice Shipment: No


Interference Test Kit EXTRA
Description:
Interference Test Kit EXTRA_x000D__x000D_ _x000D_
_x000D_ Package Content_x000D__x000D_ _x000D_Catalog number: _x000D_K2010008 _x000D__x000D_ _x000D_Lot number: _x000D_Batch Dependent _x000D__x000D_ _x000D_ _x000D_Expiration date: _x000D_Batch Dependent _x000D__x000D_ _x000D_
_x000D__x000D_ _x000D_Substance _x000D_Concentration _x000D_Diluent _x000D_Volume/Amount _x000D__x000D_ _x000D_Biotin _x000D_200 ug/mL _x000D_Diluent A _x000D_1 mL _x000D__x000D_ _x000D_Creatinine _x000D_50 mg/mL _x000D_Diluent A _x000D_1 mL _x000D__x000D_ _x000D_EDTA _x000D_500 mM (190 mg/mL) _x000D_Diluent A _x000D_1 mL _x000D__x000D_ _x000D_Glucose _x000D_250 mg/mL _x000D_Diluent A _x000D_1 mL _x000D__x000D_ _x000D_Glycerol _x000D_10 mg/mL _x000D_Diluent A _x000D_1 mL _x000D__x000D_ _x000D_Intralipid _x000D_20 % (w/v) _x000D_Diluent A _x000D_1 mL _x000D__x000D_ _x000D_Pyruvate _x000D_20 mg/mL _x000D_Diluent A _x000D_1 mL _x000D__x000D_ _x000D_Urea _x000D_200 mg/mL _x000D_Diluent A _x000D_1 mL _x000D__x000D_ _x000D_Cholesterol _x000D_na _x000D_na _x000D_100 mg powder _x000D__x000D_ _x000D_ _x000D_Diluent A _x000D_na _x000D_na _x000D_2 mL _x000D__x000D_ _x000D_
_x000D__x000D_ _x000D_Other names: _x000D_Endogenous Substances Interference Test Kit,Interference testing in clinical chemistry _x000D__x000D_ _x000D_Keywords: _x000D_Biotin, Creatinine, EDTA, Glucose, Glycerol, Intralipid, Pyruvate, Urea, Cholesterol, Interferent, Interference, interference edta urea _x000D__x000D_ _x000D_Shelf-life _x000D_12 months _x000D__x000D_ _x000D_ _x000D_Storage: _x000D_-20°C _x000D_All Interference Products Brochure_x000D_
_x000D_
_x000D_
References
_x000D_- _x000D_
- Schiettecatte, J., Anckaert, E., and Smitz, J. (2012). Interferences in Immunoassays. Advances in Immunoassay Technology. _x000D_
- Miller, J. J., and Levinson, S. S. (1996). Interferences In Immunoassays. Immunoassay, 165–190. _x000D_
- Ward, G. (2013). Rational investigations of immunoassay interferences. Pathology, 45. _x000D_
- Park, J. Y., and Kricka, L. J. (2013). Interferences in Immunoassay. The Immunoassay Handbook, 403–416. _x000D_
- EP07: Interference Testing in Clinical Chemistry. (2020). Retrieved from https://clsi.org/standards/products/method-evaluation/documents/ep07/. _x000D_
- Gilles A, Frechin L, Natchiar K, Biondani G, Loeffelholz OV, Holvec S, Malaval JL, Winum JY, Klaholz BP, Peyron JF. Targeting the Human 80S Ribosome in Cancer: From Structure to Function and Drug Design for Innovative Adjuvant Therapeutic Strategies. Cells. 2020 Mar 5;9(3). pii: E629. _x000D_
- Coussens NP, Auld D, Roby P, Walsh J, Baell JB, Kales S, Hadian K, Dahlin JL. Compound-Mediated Assay Interferences in Homogenous Proximity Assays. Assay Guidance Manual [Internet]. Bethesda (MD): Eli Lilly & Company and the National Center for Advancing Translational Sciences; 2004-. 2020 Feb 1. _x000D_
- Wang L, Zhang J, An X, Duan H. Recent progress on the organic and metal complex-based fluorescent probes for monitoring nitric oxide in living biological systems. Org Biomol Chem. 2020 Feb 26;18(8):1522-1549. _x000D_
Short Description:
Catalog #: K2010008Weight:
0.15Length:
2Width:
0.5Height:
0.5Height :
0.5