Products for Research Use Only

Corticosterone EIA Kit

CAT: 0400-SKT-205-96Size: 96 WellDry Ice: NoHazardous: No
Product image 1
1 / 1
CAT#:0400-SKT-205-96Size:96 Well
Selected
24/48H Stock Items & 2 to 6 Weeks non Stock Items.
Quick Request Actions
Background
Corticosterone (C₂₁H₃₀O₄) is a glucocorticoid hormone secreted by the adrenal cortex in response to ACTH stimulation. It is the primary stress hormone in rodents and a precursor to aldosterone. In neuroscience research, corticosterone is widely used to model chronic stress and its effects on brain function. Elevated corticosterone levels have been shown to impair memory retrieval, alter sleep-wake cycles, and exacerbate neurodegenerative processes. In Parkinson’s disease models, chronic corticosterone exposure increases alpha-synuclein phosphorylation and aggregation, particularly in the hypothalamus, and contributes to dopaminergic neuron loss. These findings highlight corticosterone’s role in stress-induced neurotoxicity and its relevance in studying the pathophysiology of neurodegenerative and psychiatric disorders.
Description
Colorimetric detection of corticosterone
Overview
The Corticosterone EIA kit is designed to quantitatively measure Corticosterone present in serum, plasma, urine, extracted dried fecal samples, and tissue culture media samples. This kit measures total corticosterone in serum and plasma and in extracted fecal samples. A corticosterone stock solution is provided to generate a standard curve for the assay and all samples should be read off the standard curve. We provide protocols on page 8 to prepare assay standards from 5,000 to 78.125 pg/mL or from 10,000 to 78.125 pg/mL. Please choose the standard range that fits your sample concentrations most appropriately. Standards or diluted samples are pipetted into a clear microtiter plate coated with an antibody to capture sheep antibodies. A corticosterone-peroxidase conjugate is added to the standards and samples in the wells. The binding reaction is initiated by the addition of a polyclonal antibody to corticosterone to each well. After an hour incubation the plate is washed and substrate is added. The substrate reacts with the bound corticosterone-peroxidase conjugate. After a short incubation, the reaction is stopped and the intensity of the generated color is detected in a microtiter plate reader capable of measuring 450nm wavelength. The concentration of the corticosterone in the sample is calculated, after making suitable correction for the dilution of the sample, using software available with most plate readers.
CAS Number
7732-18-5
Product Name Alternative
(11β) -11,21-dihydroxypregn-4-ene-3,20-dione
UNSPSC
12352203
UN Code
Non-hazardous
Hazard Statement
Non-hazardous
Species Reactivity
Species Independent
Target
Corticosterone EIA Kit
Type
EIA Kits
Applications
EIA kit used to measure the corticosterone present in samples.
Field of Research
Cell Signaling | Cancer | Oxidative Stress | Neuroscience
Detection Method
Colorimetric Assay
Assay Type
Sandwich EIA (Enzyme Immunoassay)
Assay Protocol
The Corticosterone EIA kit is designed to quantitatively measure Corticosterone present in serum, plasma, urine, extracted dried fecal samples, and tissue culture media samples. This kit measures total corticosterone in serum and plasma and in extracted fecal samples. A corticosterone stock solution is provided to generate a standard curve for the assay and all samples should be read off the standard curve. We provide protocols on page 8 to prepare assay standards from 5,000 to 78.125 pg/mL or from 10,000 to 78.125 pg/mL. Please choose the standard range that fits your sample concentrations most appropriately. Standards or diluted samples are pipetted into a clear microtiter plate coated with an antibody to capture sheep antibodies. A corticosterone-peroxidase conjugate is added to the standards and samples in the wells. The binding reaction is initiated by the addition of a polyclonal antibody to corticosterone to each well. After an hour incubation the plate is washed and substrate is added. The substrate reacts with the bound corticosterone-peroxidase conjugate. After a short incubation, the reaction is stopped and the intensity of the generated color is detected in a microtiter plate reader capable of measuring 450nm wavelength. The concentration of the corticosterone in the sample is calculated, after making suitable correction for the dilution of the sample, using software available with most plate readers.
Sample Type
Serum | EDTA Plasma | Heparin Plasma | Urine | Tissue Culture Media | Dried Fecal Samples
Sample Volume
39 samples in duplicate
Detection Range
78.125 - 10,000 pg/ml
Precision
Intra Assay Precision: Four human samples were diluted with Assay Buffer and run in replicates of 20 in an assay. The mean and precision of the calculated Corticosterone concentrations were: Sample 1- 2460.6 pg/mL, 6.3% CV Sample 2- 601.5 pg/mL, 6.5% CV Sample 3- 371.6 pg/mL, 3.1% CV Sample 4- 259.0 pg/mL, 4.8% CV Inter Assay Precision: Three human samples were diluted with Assay Buffer and run in duplicates in fourteen assays run over multiple days by four operators. The mean and precision of the calculated Corticosterone concentrations were: Sample 1- 2618.3 pg/mL, 7.5% CV Sample 2- 630.1 pg/mL, 6.4% CV Sample 3- 267.9 pg/mL, 9.9% CV
Sensitivity
18.6 pg/ml
Weight
300
Components
SKC-205A | SKC-205B | SKC-205C | SKC-205D | SKC-205E | SKC-205F | SKC-205G | SKC-205H | SKC-205I | SKC-205J
Precautions
Not for use in humans. Not for use in diagnostics or therapeutics. For in vitro research use only.
References & Citations
1. Hupé, JM, et al. Nature, 1998; 394: 784-787. 2. Kitaysky AS, Kitaiskaia EV, Wingfield JC, Piatt JF. J. Comp. Physiol, 2001; 171: 701-709. 3. Thellin O, Noel G, Khuana S, Ogle CK and Horseman ND. Shock, 2001; 16(5): 393-397. 4. Krame, KM. and Sothern RB. Chronobiol. Int., 2001; 18(6): 933-945. 5. Vazquez-Palacios G, et al. Pharmacol. Biochem Behavior, 2001: 70(2-3): 305-310.
Shipping Conditions
Blue Ice
Storage Conditions
4ºC and -20ºC
Background Reference 01
1. Hupé, J. M., James, A. C., Payne, B. R., Lomber, S. G., Girard, P., & Bullier, J. (1998) . Cortical feedback improves discrimination between figure and background by V1, V2, and V3 neurons. Nature, 394 (6695), 784–787. DOI: 10.1038/29555 2. Kitaysky, A. S., Kitaiskaia, E. V., Wingfield, J. C., & Piatt, J. F. (2001) . Dietary restrictions cause chronic elevation of corticosterone and enhance stress response in red-legged kittiwake chicks. Journal of Comparative Physiology B, 171 (8), 701–709. DOI: 10.1007/s003600100230 3. Thellin, O., Noel, G., Khuana, S., Ogle, C. K., & Horseman, N. D. (2001) . Stress hormone secretion and gut signal transducer (STAT) proteins after burn injury in rats. Shock, 16 (5), 393–397. DOI: 10.1097/00024382-200116050-00001 4. Kramer, K. M., & Sothern, R. B. (2001) . Circadian characteristics of corticosterone secretion in red-backed voles (Clethrionomys gapperi) . Chronobiology International, 18 (6), 933–945. DOI: 10.1081/CBI-100107542 5. Vazquez-Palacios, G., Retana-Márquez, S., Bonilla-Jaime, H., & Velázquez-Moctezuma, J. (2001) . Further definition of the effect of corticosterone on the sleep-wake pattern in the male rat. Pharmacology, Biochemistry, and Behavior, 70 (2–3), 305–310. DOI: 10.1016/S0091-3057 (01) 00629-8 6. Bimpos, N. M., Xie, Y., Gomez-Isla, T., Domenger, D., & Hyman, B. T. (2024) . Alpha-synuclein-induced stress sensitivity renders the Parkinson’s disease brain susceptible to neurodegeneration. Acta Neuropathologica Communications, 12, 100. DOI: 10.1186/s40478-024-01797-w. 7. Burtscher, J., Copin, J. C., Rodrigues, J., & Pernet, N. (2019) . Chronic corticosterone aggravates behavioral and neuronal symptomatology in a mouse model of alpha-synuclein pathology. Neurobiology of Aging, 83, 11–20. DOI: 10.1016/j.neurobiolaging.2019.08.011
Species
Species Independent
Quantity
1 Each | 125 µl | 3 ml | 3 ml | 28 ml | 1 ml | 30 ml | 11 ml | 5 ml | 1 Each
Platform
Microplate

Alternative Products