Products for Research Use Only

CLIA Kit for Transferrin (TF)

CAT: 0338-TRV-046548-01Size: 24 TestsDry Ice: NoHazardous: No
Product image 1
1 / 1
CAT#:0338-TRV-046548-01Size:24 Tests
Selected
24/48H Stock Items & 2 to 6 Weeks non Stock Items.
Quick Request Actions
Product Name Alternative
TRF; Siderophilin; Serotransferrin; Beta-1 metal-binding globulin
UniProt
P02787
Applications
Chemiluminescent immunoassay for Antigen Detection.
Field of Research
Tumor immunity; Infection immunity; Immune molecule
Assay Principle
The microplate provided in this kit has been pre-coated with an antibody specific to Transferrin (TF) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Transferrin (TF) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Transferrin (TF) level in the sample or standard.
Assay Protocol
1. Prepare all reagents, samples and standards;
2. Add 100µ L standard or sample to each well. Incubate 2 hours at 37° C;
3. Aspirate and add 100µ L prepared Detection Reagent A. Incubate 1 hour at 37° C;
4. Aspirate and wash 3 times;
5. Add 100µ L prepared Detection Reagent B. Incubate 30 minutes at 37° C;
6. Aspirate and wash 5 times;
7. Add 100µ L Substrate Solution. Incubate 10 minutes at 37° C;
8. Read RLU value immediately.
Assay Performance Time
2h, 40min
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Detection Range
0.14-100ng/mL
Precision
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Transferrin (TF) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Transferrin (TF) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV
Sensitivity
The minimum detectable dose of this kit is typically less than 0.07ng/mL
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Format
48T, 96T, 96Tx5, 96Tx10, 96Tx100
Specificity
This assay has high sensitivity and excellent specificity for detection of Transferrin (TF) . No significant cross-reactivity or interference between Transferrin (TF) and analogues was observed.
Product Name Synonym
Transferrin
Method
Double-antibody Sandwich
Organism Species
Homo sapiens (Human)

UniProtKB · P02787

Serotransferrin

TRFE_HUMAN · Homo sapiens

View on UniProt ↗
Primary accession
P02787
Review status
UniProtKB reviewed (Swiss-Prot)
Gene
TF
Protein existence
1: Evidence at protein level
Organism
Homo sapiens (Human)
Taxonomy ID
9606
Alternative names
Transferrin
EC number
—
Processing
Precursor
Secondary accessions
O43890, Q1HBA5, Q9NQB8, Q9UHV0
Protein keywords

Technical term

3D-structureDirect protein sequencingProteomics identificationReference proteome

Disease

Disease variant

PTM

Disulfide bondGlycoproteinMethylationPhosphoprotein

Biological process

Ion transportIron transportTransport

Ligand

IronMetal-binding

Domain

RepeatSignal

Cellular component

Secreted