Preparative HPLC
CAT:
1326-37-PHP100
Size:
1 Each
Price:
Ask
- Availability: 24/48H Stock Items & 2 to 6 Weeks non Stock Items.
- Dry Ice Shipment: No


Preparative HPLC
Description:
Preparative HPLC is equipped with 4 pump head variation and a UV or RI detector with a wavelength range of 190 to 400 nm and 400 to 800 nm. Built in multi positioned fraction valve and controlled fractionation optimizes controlled fraction collection and solvent recycling. With a column size of 10 x 1000 mm the retention, resolution and selectivity is optimized.Specifications:
Dimension: 750 x 860 x 1280 mm (100 ml, 250 ml, 500 ml, 1000 ml), 810 x 950 x 1310 mm (3 L) Wetted material: 316 L and PTFE Power: < 1500 W Mobility: With castorApplications:
Used for purification of peptides and proteins, separation of high molecular mass compounds, separation of protein mixtures, qualitative and quantitative determination of a compound, automated fraction re-analysisFeatures & Benefits:
Pump Specifications :Model NoSPH-A10SPH-A11SPH-A12SPH-A13Flow rate range0.001 ~ 50 ml / min0.001 ~ 50 ml / min0.001 ~ 100 ml / min0.001 ~ 100 ml / minMaximum pressure30 MPa30 MPa15 MPa10 MPaFlow rate accuracy± 0.35± 0.5± 0.5± 0.5Flow rate repeatability %≤ 0.1≤ 0.15≤ 0.1≤ 0.15Column size10 x 250 mm10 x 250 mm10 x 250 mm10 x 250 mmSample loading35 ~ 60 mg35 ~ 60 mg35 ~ 60 mg35 ~ 60 mgPressure pulsation1 % at 10 MPa1.5 % at 10 MPa1.5 % at 10 MPa1.5 % at 10 MPaFlow rate repeatability %≤ 0.1≤ 0.15Gradient accuracy %± 2± 2± 2± 2Gradient repeatability %≤ 0.2≤ 0.2≤ 0.2≤ 0.2Dimension465 x 315 x 180 mm455 x 265 x 190 mm465 x 315 x 180 mm465 x 315 x 180 mmPower150 W150 W150 W150 WPower supply90 V ~ 240 V/ 50 Hz90 V ~ 240 V/ 60 Hz90 V ~ 240 V/ 50 Hz90 V ~ 240 V/ 60 HzWeight11.6 kg11.2 kg11.6 kg11.6 kg Detector Specifications :Model NoSPH-A20SPH-A21SPH-A22Wavelength range190 to 800 nm190 to 800 nm190 to 800 nmWavelength accuracy± 0.5 nm± 1 nm± 0.75 nmWavelength repeatability0.15 nm0.3 nm0.2 nmBand width8 nm8 nm8 nmOptical pathSemi flow / analyticalSemi flow / analyticalSemi flow / analyticalBaseline noise (Static) Au≤ ± 0.35 x 10 -5≤ ± 0.5 x 10 -5≤ ± 0.5 x 10 -5Baseline drift (Static) Au / h≤ 1 x 10 -4≤ 1.5 x 10 -4≤ 1.5 x 10 -4Minimum detection limit≤ 4 x 10 -8≤ 4 x 10 -8≤ 4 x 10 -8Power150 W150 W150 WPower supply90 V / 50 ~ 60 Hz90 V / 50 ~ 60 Hz90 V / 50 ~ 60 HzDimension465 x 315 x 180 mm465 x 315 x 180 mm460 x 265 x 190 mmWeight9.5 kg9.5 kg9.2 kg Column Specifications :Inner diameter100 mm, 20 mm, 30 mm, 50 mmColumn length100 mm, 150 mm, 250 mm, 300 mmParticle size5 µm, 10 µm