HPLC System

CAT:
1326-37-HPS103
Size:
1 Each
  • Availability: 24/48H Stock Items & 2 to 6 Weeks non Stock Items.
  • Dry Ice Shipment: No
HPLC System - image 1

HPLC System

  • Description:

    HPLC System 37-HPS103 delivers high-quality performance and reliable results in order to meet the stringent requirements of the customer. To meet GMP/GLP requirements of the instrument, this HPLC system has hardware with VP function which records maintenance information and operations.
  • Specifications:

    High pressure pump: High pressure constant-current infusion pump Infusion Way: Micro volume series dual-piston Infusion pressure: 0 to 9999 Psi Flow rate: ≤ 0.5 % Flow rate range: 0.001 to 9.999 mL / min (in 0.001 mL / min increments) Stability error for the flow rate: ≤ 0.2 % RSD Gradient error: ± 1 % (0 to 100 % water/acetone solvent) Pressure pulsation: < 15 Psi (flow rate 1 mL / min, pressure 600 to 1600 Psi) Air tightness: Pressure 5400 Psi, 10 min time, pressure drop < 400 Psi Time program function: Yes Size (W x H x D) : 260 x 130 x 420 mm Weight: 11 kg Operation temperature: 4 to 40 ºC UV detector: a:18:{s:16:"Wavelength range"; s:3:"240"; s:16:"Wavelength error"; s:8:"≤ 1 nm"; s:30:"Wavelength repeatability error"; s:13:"≤ ± 0.1 nm"; s:13:"Dynamic noise"; s:77:"≤ ± 0.75 x 10-5AU (methyl alcohol 1 mL / min, 254 nm, 20 ºC) "; s:12:"Static noise"; s:77:"≤ ± 0.5 x 10-5A (empty cell, response time, 1 second, 20 ºC) "; s:22:"Dynamic baseline Drift"; s:78:"≤ ± 1 x 10-4AU / h (methyl alcohol 1 mL / min, 254 nm, 20 ºC) "; s:21:"Static baseline Drift"; s:73:"≤ 0.5 x 10-4 (empty cell, response time, 1 second, 20 ºC) "; s:12:"Linear range"; s:7:"≥ 104"; s:18:"Limit of detection"; s:69:"≤ 1 x 10-9g / ml (Naphthalene methyl alcohol solvent) "; s:26:"Quantitative repeatability"; s:15:"RSD 6 ≤ 0.1 %"; s:25:"Qualitative repeatability"; s:15:"RSD 6 ≤ 0.5 %"; s:19:"Spectrum band width"; s:4:"6 nm"; s:16:"Flow cell volume"; s:5:"8 µL"; s:12:"Optical path"; s:5:"10 nm"; s:21:"Time program function"; s:3:"Yes"; s:18:"Size (W x H x D) "; s:20:"260 x 130 x 420 mm"; s:6:"Weight"; s:5:"11 kg"; s:21:"Operation Temperature"; s:10:"4 - 40 ºC"; }
  • Applications:

    HPLC System 37-HPS103 is used in scientific research studies, detection of residual amounts in medicine, food, and alcohol, and in chemical analysis.
  • Features & Benefits:

    Dimension :750 x 860 x 1280 mm (100 ml, 250 ml, 500 ml, 1000 ml), 810 x 950 x 1310 mm (3 L) Wetted material :316 L and PTFE Power :< 1500 W Mobility :With castor