MMP9 High Sensitivity ELISA Kit (Horse)

CAT:
247-OKCD01327-96W
Size:
96 Well
  • Availability: 24/48H Stock Items & 2 to 6 Weeks non Stock Items.
  • Dry Ice Shipment: No
MMP9 High Sensitivity ELISA Kit (Horse) - image 1

MMP9 High Sensitivity ELISA Kit (Horse)

  • Reproducibility:

    Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level High Sensitive Matrix Metalloproteinase 9 (MMP9) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level High Sensitive Matrix Metalloproteinase 9 (MMP9) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
  • Gene Name:

    Matrix metallopeptidase 9
  • Gene Aliases:

    92 kDa gelatinase; gelatinase B; matrix metalloproteinase 9; matrix metalloproteinase-9; type IV collagenase.
  • Gene ID:

    100056599
  • Accession Number:

    NP_001104772.1
  • Reactivity:

    Equus caballus|Horse
  • Type:

    ELISA Kit
  • Applications:

    Enzyme-linked Immunosorbent assay-Sandwich
  • Detection Method:

    Colorimetric
  • Assay Principle:

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Matrix Metalloproteinase 9 (MMP9) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Matrix Metalloproteinase 9 (MMP9) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Matrix Metalloproteinase 9 (MMP9), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of High Sensitive Matrix Metalloproteinase 9 (MMP9) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
  • Assay Protocol:

    Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Antibody Array (AA) Protocol
  • Sample Type:

    Serum, plasma, tissue homogenates and other biological fluids
  • Detection Range:

    15.6-1000pg/mL
  • Recovery:

    Matrix Recovery range (%) Average (%) Serum (n=5) 78-93 81 Heparin Plasma (n=5) 91-103 94 Matrix Recovery range (%) Average (%) Matrix Recovery range (%) Average (%) Serum (n=5) 78-93 81 Serum (n=5) 78-93 81 Heparin Plasma (n=5) 91-103 94 Heparin Plasma (n=5) 91-103 94
  • Sensitivity:

    5.9 pg/mL
  • Reconstitution:

    2°C to 8°C|-20°C
  • Components:

    Component Amount Anti-MMP9 Microplate 96 Wells (12 x 8 Well Strips) MMP9 Lyophilized Standard 2 100X Biotinylated MMP9 Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Component Amount Component Amount Anti-MMP9 Microplate 96 Wells (12 x 8 Well Strips) Anti-MMP9 Microplate 96 Wells (12 x 8 Well Strips) MMP9 Lyophilized Standard 2 MMP9 Lyophilized Standard 2 100X Biotinylated MMP9 Detector Antibody 120 uL 100X Biotinylated MMP9 Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Stop Solution 1 x 6 mL
  • Specificity:

    This assay has high sensitivity and excellent specificity for detection of Matrix Metalloproteinase 9 (MMP9) . No significant cross-reactivity or interference between Matrix Metalloproteinase 9 (MMP9) and analogues was observed.
  • NCBI Gene Symbol:

    MMP9
  • Protein Name:

    MMP9
  • Gene Name URL:

    MMP9
  • CAS Number:

    7732-18-5
  • Nucleotide Accession Number:

    NM_001111302.1