Reproducibility
Sample Oxytocin Conc. (pg/mL) %CV 1 1,391.0 5.2% 2 193.8 4.3% Sample Oxytocin Conc. (pg/mL) %CV Sample Oxytocin Conc. (pg/mL) %CV 1 1,391.0 5.2% 1 1,391.0 5.2% 2 193.8 4.3% 2 193.8 4.3% Sample Oxytocin Conc. (pg/mL) %CV 1 1,334.0 7.7% 2 205.7 10.0% Sample Oxytocin Conc. (pg/mL) %CV Sample Oxytocin Conc. (pg/mL) %CV 1 1,334.0 7.7% 1 1,334.0 7.7% 2 205.7 10.0% 2 205.7 10.0%
CAS Number
7732-18-5
Gene Name
Oxytocin
Type
ELISA Kit
Applications
Enzyme-linked immunosorbent assay
Assay Principle
The DetectX® Oxytocin Immunoassay Kit is designed to quantitatively measure Oxytocin present in serum, plasma, saliva, clarified milk and tissue culture media samples. Please read the complete kit insert before performing this assay. An oxytocin standard is provided to generate a standard curve for the assay and all samples should be read off the standard curve. Standards or diluted samples are pipetted into a clear microtiter plate coated with an antibody to capture rabbit antibodies. An oxytocin-peroxidase conjugate is added to the standards and samples in the wells. The binding reaction is initiated by the addition of a polyclonal antibody to oxytocin to each well. After an overnight incubation at 4C the plate is washed and supplied substrate is added. The substrate reacts with the bound oxytocin-peroxidase conjugate. After a 30 minute incubation, the reaction is stopped and the intensity of the generated color is detected in a microtiter plate reader capable of measuring 450nm wavelength. The concentration of the oxytocin in the sample is calculated, after making suitable correction for the dilution of the sample, using software available with most plate readers.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Antibody Array (AA) Protocol
Sample Type
Serum, Plasma, Saliva, Clarified Milk, and Tissue Culture Media
Sensitivity
17.0 pg/mL
Reconstitution
2°C to 8°C
Components
Component Quantity Coated Clear 96 Well Plates 1 or 5 Each Oxytocin Standard 125 uL or 625 uL DetectX® Oxytocin Antibody 3 mL or 13 mL DetectX® Oxytocin Conjugate 3 mL or 13 mL Assay Buffer Concentrate 28 mL or 55 mL Extraction Solution 50 mL or 250 mL Wash Buffer Concentrate 30 mL or 125 mL TMB Substrate 11 mL or 55 mL Stop Solution 5 mL or 25 mL Plate Sealer 1 or 5 Each Component Quantity Component Quantity Coated Clear 96 Well Plates 1 or 5 Each Coated Clear 96 Well Plates 1 or 5 Each Oxytocin Standard 125 uL or 625 uL Oxytocin Standard 125 uL or 625 uL DetectX® Oxytocin Antibody 3 mL or 13 mL DetectX® Oxytocin Antibody 3 mL or 13 mL DetectX® Oxytocin Conjugate 3 mL or 13 mL DetectX® Oxytocin Conjugate 3 mL or 13 mL Assay Buffer Concentrate 28 mL or 55 mL Assay Buffer Concentrate 28 mL or 55 mL Extraction Solution 50 mL or 250 mL Extraction Solution 50 mL or 250 mL Wash Buffer Concentrate 30 mL or 125 mL Wash Buffer Concentrate 30 mL or 125 mL TMB Substrate 11 mL or 55 mL TMB Substrate 11 mL or 55 mL Stop Solution 5 mL or 25 mL Stop Solution 5 mL or 25 mL Plate Sealer 1 or 5 Each Plate Sealer 1 or 5 Each