CAT: 0247-OKAU00047-1PLATESize: 1 PlateDry Ice: NoHazardous: No
Product image 1
1 / 1
CAT#:0247-OKAU00047-1PLATESize:1 Plate
Selected
24/48H Stock Items & 2 to 6 Weeks non Stock Items.
Quick Request Actions
Reproducibility
Sample 17-Hydroxyprogesterone Conc. (pg/mL) %CV 1 1,265.7 5.4 2 450.0 6.5 3 168.5 7.9 Sample 17-Hydroxyprogesterone Conc. (pg/mL) %CV Sample 17-Hydroxyprogesterone Conc. (pg/mL) %CV 1 1,265.7 5.4 1 1,265.7 5.4 2 450.0 6.5 2 450.0 6.5 3 168.5 7.9 3 168.5 7.9 Sample 17-Hydroxyprogesterone Conc. (pg/mL) %CV 1 1,204.8 7.0 2 444.1 6.5 3 162.9 10.6 Sample 17-Hydroxyprogesterone Conc. (pg/mL) %CV Sample 17-Hydroxyprogesterone Conc. (pg/mL) %CV 1 1,204.8 7.0 1 1,204.8 7.0 2 444.1 6.5 2 444.1 6.5 3 162.9 10.6 3 162.9 10.6
CAS Number
7732-18-5
Gene Name
17-Hydroxyprogesterone
Type
ELISA Kit
Applications
Enzyme-linked immunosorbent assay
Assay Principle
The DetectX® 17-Hydroxyprogesterone Immunoassay kit uses a specifically generated antibody to measure 17-Hydroxyprogesterone (17HO-P) and its metabolites in urine and fecal samples, or in extracted serum and plasma. This kit is not recommended for serum or plasma samples without extraction. The kit will quantitatively measure 17HO-P present in reconstituted buffer samples and tissue culture media samples. Please read the complete kit insert before performing this assay. A 17HO-P standard is provided to generate a standard curve for the assay and all samples should be read off the standard curve. Standards or diluted samples are pipetted into a clear microtiter plate coated with an antibody to capture sheep antibodies. A 17HO-P-peroxidase conjugate is added to the standards and samples in the wells. The binding reaction is initiated by the addition of a polyclonal antibody to 17HO-P to each well. After an hour incubation the plate is washed and substrate is added. The substrate reacts with the bound 17HO-P-peroxidase conjugate. After a short incubation, the reaction is stopped and the intensity of the generated color is detected in a microtiter plate reader capable of measuring 450 nm wavelength. The concentration of the 17HOP in the sample is calculated, after making suitable correction for the dilution of the sample, using software available with most plate readers.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Antibody Array (AA) Protocol
Sample Type
Dried Fecal Extracts, Urine, Extracted Serum/Plasma, and Tissue Culture Media
Sensitivity
20.3 pg/mL
Reconstitution
2°C to 8°C
Components
Component Quantity Coated Clear 96 Well Plate 1 or 5 Each 17-Hydroxyprogesterone Standard 70 uL or 350 uL DetectX® 17-Hydroxyprogesterone Antibody 3 mL or 13 mL DetectX® 17-Hydroxyprogesterone Conjugate 3 mL or 13 mL Assay Buffer Concentrate 28 mL or 55 mL Wash Buffer Concentrate 30 mL or 125 mL TMB Substrate 11 mL or 55 mL Stop Solution 5 mL or 25 mL Plate Sealer 1 or 5 Each Component Quantity Component Quantity Coated Clear 96 Well Plate 1 or 5 Each Coated Clear 96 Well Plate 1 or 5 Each 17-Hydroxyprogesterone Standard 70 uL or 350 uL 17-Hydroxyprogesterone Standard 70 uL or 350 uL DetectX® 17-Hydroxyprogesterone Antibody 3 mL or 13 mL DetectX® 17-Hydroxyprogesterone Antibody 3 mL or 13 mL DetectX® 17-Hydroxyprogesterone Conjugate 3 mL or 13 mL DetectX® 17-Hydroxyprogesterone Conjugate 3 mL or 13 mL Assay Buffer Concentrate 28 mL or 55 mL Assay Buffer Concentrate 28 mL or 55 mL Wash Buffer Concentrate 30 mL or 125 mL Wash Buffer Concentrate 30 mL or 125 mL TMB Substrate 11 mL or 55 mL TMB Substrate 11 mL or 55 mL Stop Solution 5 mL or 25 mL Stop Solution 5 mL or 25 mL Plate Sealer 1 or 5 Each Plate Sealer 1 or 5 Each