SmartDrop™ X Nano Spectrophotometer, 115V
- Availability: 24/48H Stock Items & 2 to 6 Weeks non Stock Items.
- Dry Ice Shipment: No


SmartDrop™ X Nano Spectrophotometer, 115V
Description:
SmartDrop L Ideal for basic DNA/RNA/protein quantification and purity Affordable LED and silicon detector technology Fixed 0.5mm path length, detect up to 2500ng/µl of dsDNA SmartDrop L is the affordable choice for laboratories needing to determine nucleic acid and protein concentrations and purity of samples. The LED light source and silicon photocell sensor provide readings at 260 and 280nm. Samples from 1.0 to 2.0µl are loaded directly on the pedestal. Results are provided in about 5 seconds. The software automatically calculates and displays 260/280 ratios. SmartDrop X Full-spectrum absorbance scans from 200 to 800nm Quickly calculates and displays 260/280 and 260/230 ratios Long-life Xenon lamp with precision monochromator Auto-ranging path lengths of 0.2mm and 1.0mm Detect up to 4,500 ng/µl of dsDNA without dilution A full spectrum UV-Vis spectrophotometer, SmartDrop X requires 0.5 to 2.0µl of sample. In addition to nucleic acid and protein calculations, the software has preset programs for BCA, Bradford and Lowry assays. A full spectrum analysis can be performed in about 6 seconds, aiding in the identification of unknowns. Up to 5 specific points on the spectrum can be selected for colorimetric readings output. The long life Xenon lamp source requires no warm up and is paired with a highly sensitive CCD detector. To provide the most accurate results, the SmartDrop X utilizes 2 path lengths. SmartDrop XF – Spectrophotometer + Fluorometer Full-spectrum absorbance scanning and calculations of 260/280 and 260/230 ratios Long-life Xenon lamp with precision monochromator Auto-ranging path lengths of 0.05mm, 0.2mm and 1.0mm Detect up to 15,000ng/µl of dsDNA without dilution Integrated fluorometer for sensitive quantitation of low concentration nucleic acids This top of the line spectrophotometer can perform not only UV-Vis readings in the range of 200-800nm but also fluorescence readings. Like the SmartDrop X, the SmartDrop XF features predefined programs for nucleic acids, proteins, and various colorimetric assays. The patented, motorized system gently stretches the sample column and allows for three different path lengths, providing accurate readings of samples from 0.5 to 2.0µl without dilution. The integrated fluorometer yields more accurate, sensitive and selective quantitation of nucleic acids. The blue light channel (460nm) is useful for detection of dyes such as PicoGreen and RiboGreen as well as GFP and fluorescein. UV, green and red channel models are available upon request. Accuris DNA Quantification Kits Accuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using instruments such as the Qubit®, SmartDrop™ XF, and microplate readers. The reagents are highly selective for double-stranded DNA (dsDNA) ; quantification results will not be skewed by single-stranded DNA (ssDNA), RNA, protein, or nucleotides in a sample. Included with each kit are a concentrated fluorescent assay reagent, dilution buffer, and ready-to-use DNA standards. The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL), and the concentration determined using an appropriate fluorometer instrument that utilizes blue excitation (460 ± 20 nm) and measures green fluorescence (525-570 nm) . High Sensitivity dsDNA Assay Kit The Accuris High Sensitivity Kit provides an accurate method to quantify low concentration dsDNA samples. The assay kit is designed to be accurate for initial DNA sample concentrations of 0.005–120 ng/µl, providing a detection range of 0.1–120 ng. Broad Range dsDNA Assay Kit The Accuris Broad Range Kit provides an accurate method to quantify dsDNA samples that have a broad concentration range starting at 0.2 ng/µL. The assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng/µL, providing a detection range of 4−2,000 ng.Specifications:
Display 7-inch touch screen Minimum sample size 0.5µl – 2.0µl Path length 0.2mm, 1.0mm Light source Xenon Flash Lamp Detector 2048 Element Linear Silicon CCD Array Wavelength 200 – 800nm (1nm steps) Absorbance range 00.04 – 90 A (10mm equivalent) Absorbance precision 0.003 A Lower limit of detection dsDNA: 2ng/µl; BSA: 0.1mg/ml Upper limit of detection dsDNA: 4,500ng/µl; BSA: 135mg/ml Detection time < 5 seconds Communication ports USB for data export Voltage input DC 24V, 2A Power 25W Dimensions (WxDxH) 8.3 x 10.6 x 7.2 in. / 21.0 x 26.8 x 18.1cm Weight 2.8 kg / 6.2 lbs Cuvette OD600 detection Absorbance range 0.0 – 4.0 A Absorbance stability [0,3) ≤ 0.5%, [3,4) ≤ 2% Absorbance repeatibility [0,3) ≤ 0.5%, [3,4) ≤ 2% Absorbance precision [0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2%Standard:
Quick and accurate results from a sample droplet Touch screen control panel, no PC or software required Built-in printer and cuvette port for OD600 readings XF model includes fluorometer for sensitive DNA quantificationStorage Conditions:
10 to 30°CShipping Width:
50,8 cmShipping Height:
33.02Shipping Length:
50,8 cmWarranty:
2 yearsShipping Weight:
9.5
