Ascorbic Acid for Interference Testing

| Catalog number: | _x000D_K2010001A | _x000D_
| Lot number: | _x000D_Batch Dependent | _x000D_
| Expiration date: | _x000D_Batch Dependent | _x000D_
| Volume: | _x000D_1 mL | _x000D_
| Appearance: | _x000D_Clear Solution | _x000D_
| Concentration: | _x000D_176 mg/mL (1.0 M) in diluent A (provided) | _x000D_
| Molar Mass | _x000D_176.12 g/mol | _x000D_
| Storage: | _x000D_At -20°C or lower. Avoid repeated freeze-thaw cycles. Aliquot as needed. | _x000D_
| Other names: | _x000D_Ascorbate, L-ascrobate, L-ascorbic acid | _x000D_
All Interference Products Brochure_x000D_
_x000D_
_x000D_
_x000D_
References_x000D_
- _x000D_
- Schiettecatte, J., Anckaert, E., and Smitz, J. (2012). Interferences in Immunoassays. Advances in Immunoassay Technology. _x000D_
- Miller, J. J., and Levinson, S. S. (1996). Interferences In Immunoassays. Immunoassay, 165–190. _x000D_
- Ward, G. (2013). Rational investigations of immunoassay interferences. Pathology, 45. _x000D_
- Park, J. Y., and Kricka, L. J. (2013). Interferences in Immunoassay. The Immunoassay Handbook, 403–416. _x000D_
- EP07: Interference Testing in Clinical Chemistry. (2020). Retrieved from https://clsi.org/standards/products/method-evaluation/documents/ep07/. _x000D_
- Gilles A, Frechin L, Natchiar K, Biondani G, Loeffelholz OV, Holvec S, Malaval JL, Winum JY, Klaholz BP, Peyron JF. Targeting the Human 80S Ribosome in Cancer: From Structure to Function and Drug Design for Innovative Adjuvant Therapeutic Strategies. Cells. 2020 Mar 5;9(3). pii: E629. _x000D_
- Coussens NP, Auld D, Roby P, Walsh J, Baell JB, Kales S, Hadian K, Dahlin JL. Compound-Mediated Assay Interferences in Homogenous Proximity Assays. Assay Guidance Manual [Internet]. Bethesda (MD): Eli Lilly & Company and the National Center for Advancing Translational Sciences; 2004-._x000D_ 2020 Feb 1. _x000D_
- Wang L, Zhang J, An X, Duan H. Recent progress on the organic and metal complex-based fluorescent probes for monitoring nitric oxide in living biological systems. Org Biomol Chem. 2020 Feb 26;18(8):1522-1549. _x000D_
- Kawasaki H, Suzuki T, Ito K, Takahara T, Goto-Inoue N, Setou M, Sakata K, Ishida N. Minos-insertion mutant of the Drosophila GBA gene homologue showed abnormal phenotypes of climbing ability, sleep and life span with accumulation of hydroxy-glucocerebroside. Gene. 2017 May 30;614:49-55. _x000D_
- Hull B. Aberrantly elevated TSH level due to human anti-mouse antibodies (HAMA) interference with thyrotropin assay. J S C Med Assoc. 2012 Feb;108(1):12-3. _x000D_
- Degn SE, Andersen SH, Jensen L, Thiel S, Jensenius JC. Assay interference caused by antibodies reacting with rat kappa light-chain in human sera. J Immunol Methods. 2011 Sep 30;372(1-2):204-8. _x000D_
Related Products
Alternative Products
Popular Products

Anti-CDC123 Rabbit Monoclonal Antibody
SKU: 1619-01|Size: 20 μL

Histo-Clear
SKU: HS-200-01|Size: 1 L

Histo-Clear
SKU: NAT1332|Size: 5 US Gallon - 18.9 L

Diogenes
SKU: CL-202|Size: 1 Kit

OptiClear Sample Kit II
SKU: OE-109|Size: 1 L

Glycosaminoglycans Assay Kit
SKU: 6022|Size: 1 Kit

0.2 mL 8-Tube Strip with Caps, Thermo Fisher Style
SKU: PCR8WC-02TN|Size: 0.2 mL

Sirius Red/Fast Green Collagen Staining Kit
SKU: 9046|Size: 30-50 Samples

Streptavidin Polystyrene Particles, 0.5% w/v, 5.0-5.9 µm
SKU: SVP-50-5|Size: 5 mL

Sirius Red/Fast Green Dye Solution, 250 ml
SKU: 90463|Size: 250 mL

Centrifuge Tube
SKU: B04|Size: 0.5 mL

Centrifuge Tube
SKU: B10|Size: 10 mL

Centrifuge Tube
SKU: B13|Size: 15 mL

Centrifuge Tube
SKU: B14|Size: 50 mL - Self Stand

Centrifuge Tube
SKU: B15|Size: 50 mL - Conical Bottom

Centrifuge Tube
SKU: B16|Size: 50 mL

Centrifuge Tube
SKU: B17|Size: 50 mL

Centrifuge tube
SKU: RTD-50-02|Size: 50 mL

Centrifuge tube
SKU: T1.5CS-01|Size: 1.5 mL

Centrifuge tube
SKU: T1.5CN-01|Size: 1.5 mL
