Products for Research Use Only

060020 Mold Count Plate (Mold Testing Strip)

CAT: 0938-060020Size: 20 Pieces/box (2 Slices / Piece)Dry Ice: NoHazardous: No
Product image 1
1 / 1
CAT#:0938-060020Size:20 Pieces/box (2 Slices / Piece)
Selected
24/48H Stock Items & 2 to 6 Weeks non Stock Items.
Quick Request Actions
Assay Protocol
1.Sample: Take 25g of crushed sample, adding 25mL of sterile saline or other diluents to mix. 2. Inoculation and culture: After appropriate dilution of the sample, open the lid counting cards, drop 1ml of sample on each paper then close the lid; After the sample completely penetrate into paper, cultivate in an incubator and put upside down the plastic box, and cultured at 28 ~ 30 °C for 48 to 72 hours, and then observe the result:paper surface showing spots or mycelium which is spore of mold colonies, calculate the number of colonies; multiplied by the dilution factor based on the average number of colonies dilution with two cards, namely per ml contained in a sample or per g mold counts. Note: 1.The selection of the appropriate dilution is a close correlation with the results . 2.The culture temperature selection: suitable temperature for the growth of mold is generally between 25 ~ 35 °C, the incubation temperature recommended by the national standard is 25 ~ 28 °C, but experimental studies with counting cards found in our company that when the incubation temperature was between 28 ~ 30 °C , the mould grow fastest.
Recommended Usage
For testing and counting of mold & yeast in water .