CLIA Kit for Apoptosis Inducing Factor (AIF)

CAT:
338-SCB064Hu-05
Size:
10x 96 Tests
  • Availability: 24/48H Stock Items & 2 to 6 Weeks non Stock Items.
  • Dry Ice Shipment: No
CLIA Kit for Apoptosis Inducing Factor (AIF) - image 1

CLIA Kit for Apoptosis Inducing Factor (AIF)

  • Product Name Alternative:

    PDCD8; Programmed Cell Death protein 8; Apoptosis-inducing factor 1, mitochondrial
  • Applications:

    Chemiluminescent immunoassay for Antigen Detection.
  • Assay Principle:

    The microplate provided in this kit has been pre-coated with an antibody specific to Apoptosis Inducing Factor (AIF) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Apoptosis Inducing Factor (AIF) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Apoptosis Inducing Factor (AIF) level in the sample or standard.;
  • Assay Protocol:

    1. Prepare all reagents, samples and standards;
    2. Add 100µ L standard or sample to each well. Incubate 2 hours at 37° C;
    3. Aspirate and add 100µ L prepared Detection Reagent A. Incubate 1 hour at 37° C;
    4. Aspirate and wash 3 times;
    5. Add 100µ L prepared Detection Reagent B. Incubate 30 minutes at 37° C;
    6. Aspirate and wash 5 times;
    7. Add 100µ L Substrate Solution. Incubate 10 minutes at 37° C;
    8. Read RLU value immediately.
  • Assay Performance Time:

    2H, 40min
  • Sample Type:

    Serum, plasma, tissue homogenates and other biological fluids
  • Detection Range:

    2.74 - 2000 pg/mL
  • Precision:

    Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Apoptosis Inducing Factor (AIF) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Apoptosis Inducing Factor (AIF) were tested on 3 different plates, 8 replicates in each plate.
    CV (%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

  • Sensitivity:

    The minimum detectable dose of this kit is typically less than 1.17pg/mL
  • Stability:

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

  • Specificity:

    This assay has high sensitivity and excellent specificity for detection of Apoptosis Inducing Factor (AIF) .
    No significant cross-reactivity or interference between Apoptosis Inducing Factor (AIF) and analogues was observed.

  • Method:

    Double-Antibody Sandwich
  • Organism Species:

    Homo sapiens (Human)