Human sCD40L PicoKine ELISA Kit

  • Catalog number
    EK0573
  • Price
    Please ask
  • Size
    1x96 well plate
  • ELISA s application
    For quantitative measurement of human soluble CD40L in cell culture supernatant, cell lysate, tissue homogenates, serum and plasma heparin, EDTA .
  • Gene tested
    Human CD40L
  • ELISA standard curve
    Concentration(pg/ml) + 0 + 62.5 + 125 + 250 + 500 + 1000 + 2000 + 4000 O.D. + 0.084 + 0.148 + 0.194 + 0.337 + 0.518 + 1.035 + 1.572 + 2.111
  • ELISA kit detection limits
    62.5pg/ml to 4000pg/ml
  • ELISA s sensitivity
    < 15pg/ml
  • Target of this ELISA
    Natural and recombinant human CD40L
  • Cross reaction
    the ELISA does not cross react with any other proteins except from closely related species
  • ELISA s precision parameters
    intra assay precisions and inter assay precisions samples;1;2;3;1;2;3 n;16;16;16;24;24;24 mean (ng/ml);0.44;1.26;2.38;0.42;1.41;2.46 ELISA standard deviations 0.026;0.064;0.145;0.029;0.086;0.182 CV(%);5.9;5.1;6.1;6.8;6.1;7.4
  • ELISA kit description
    GENTAUR's human CD40L ELISA test is a ready to use ELISA kit. We use a monoclonal from mouse specific for CD40L was used as capure antibodies on the ELISA test plate. The internal standards (E.coli, E108-L261) and your samples are measured with a biotin conjugated polyclonal from goat specific for CD40L will than be washed with PBS. The colour reaction with TMB on HRP will colour the well from blue to yellow with the stop solution. The more human CD40L in your sample the higher the ELISA signal will be compared to this elisa's standard curve.
  • Detector and capure antibodies
    a monoclonal antibodies from mouse;a biotinylated polyclonal antibodies from goat
  • The ELISA contains
    Catalog number;Description;Quantity -;96-well plate precoated with anti- human sCD40L antibodies;1 ST0000-10;Lyophilized recombinant human sCD40L standard;10ng/tubex2 AR1107;Biotinylated anti- human sCD40L antibodies;130ul(dilutions 1:100) AR1103;Avidin-Biotin-Peroxidase Complex(ABC);130ul(dilutions 1:100) AR1106-1;Sample diluent buffers;30ml AR1106-2;antibodies diluent buffers;12ml AR1106-3;ABC diluent buffers;12ml AR1104;TMB color developing agents;10ml AR1105;TMB stop solution;10ml -;Adhesive cover;4
  • Anti coagulation
    heparin or EDTA
  • How the elisa works
    Sample the amount of 100ul/well of the standard solution at 4000pg/ml, 2000pg/ml,1000pg/ml, 500pg/ml, 250pg/ml, 125pg/ml, 62.5pg/ml human CD40L standard solutions into the precoated 96-well plate. Add 0.1ml of the sample diluent buffers into the control well (Zero well). Add 0.1ml of each properly diluted sample of human cell culture supernatant, serum or plasma(heparin, EDTA) to the ELISA plate. Keep in mind that each human CD40L standard solution and each sample be measured in duplicate.
  • Minutes of TMB incubation
    15-20
  • More gene info
    CD40 ligand(CD40L) is a type II membrane protein of 261 amino acids on activated T cells that induces B cell proliferation and immunoglobulin secretion. It has homology with tumour necrosis factor-alpha and -beta, and has important functions in B-cell activation and differentiation. Human CD40L with 5 exons, is mapped to the proximal region of the mouse X chromosome on Xq26.3-27.1, and can be detected on T cells but is absent from B cells and monocytes. Since CD40L is expressed on platelets and released from them on activation, its predictive value as a marker for clinical outcome and the therapeutic effect of inhibition of glycoprotein IIb/IIIa receptor in patients with acute coronary syndromes was investigated. The soluble CD40L may be involved in the process of restenosis and that it exerts its effect by triggering a complex group of inflammatory reactions on endothelial and mononuclear cells.CD40L plays a central role in the pathophysiology of acute coronary syndromes, and has a role in the pathogenesis of coronary artery lesions.
  • Antigen
    E.coli, E108-L261
  • Keep at
    Store at 4˚C for 6 months, at -20˚C for 12 months. Avoid multiple freeze-thaw cycles(Shipped with wet ice.)
  • Uniprot
    CD40 ligand
  • Gene name
    CD40 ligand
  • Alternative
    CD154;CD40 antigen ligand;CD40 ligand;CD40-L;CD40L_HUMAN;CD40LG;gp39;HIGM1;IGM;IMD3;soluble form;T B cell activating molecule;T BAM;T cell antigen Gp39;T-cell antigen Gp39;TNF related activation protein;TNF-related activation protein;TNFSF5;TrAP;Tumor necrosis factor (ligand) superfamily member 5;Tumor necrosis factor (ligand) superfamily, member 5 (hyper-IgM syndrome);Tumor necrosis factor ligand superfamily member 5
  • Gen protein identity
    P29965
  • Entrez nr
    959
  • Properties
    E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
  • Test
    ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
  • Gene target
  • Gene symbol
    CD40LG
  • Short name
    sCD40L PicoKine ELISA Kit
  • Technique
    ELISA kit, ELISA, ELISAs Enzyme-linked immunosorbent assay 90320007 SNOMED code are used by the medical researcher for detection of human, mouse, … proteins are supplied in coated 96 well plates to be stored at +4°C. ELISA test kits can be sandwich ELISA. In sandwich ELISAS Enzyme-linked immunosorbent assay 9we use captor and detector antibodies. In single antibody ELISAs the antigen is coated and only a detector antibody is used. Traditional competition antigen ELISAs are coated with a captor antibody and a competitive antigen is labelled with the chromogen. In this case the ratio on your graph will be inverse proportional with the antigen present in your sample. A sign detected by the Colorimetric detection OD optical density absorbance at 450 nm between 0 and 4 with an ELISA reader for 450 nm absortion. Genprice Inc. the recognized authority tax ID 45-4304622 D-U-N-S number - 078440800. MeSH code E05 478 566 350 170 Enzyme-Linked Immunosorbent Assay. PROMT code 3841327 Immunoabsorbent assay tests. ELISA tests are enzyme linked immunoassays to detect human, mouse or other proteins in serum, plasma, urine or biological fluids. MeSH code E05 478 566 350 170 for Enzyme-Linked Immunosorbent Assay or ELISA kits. Also Enzyme-linked immunoassay, competitive have the SNOMED name 61461007 and the PROMT code for ELISA readers is 3841330. This is the desigation of other diagnostic analyzers and tests.
  • Host
    antigen assay ELISA kit 1 Kit (96 Wells)
  • Species
    Human, Humans
  • Alternative name
    H. sapiens sCD40L PicoKine Enzyme-linked immunosorbent assay reagent
  • Alternative technique
    elisas, kits
  • Alternative to gene target
    v-kit Hardy-Zuckerman 4 feline sarcoma viral oncogene homolog, C-Kit and CD117 and PBT and SCFR, KIT and IDBG-18980 and ENSG00000157404 and 3815, transferase activity, Extracellular, Kit and IDBG-172083 and ENSMUSG00000005672 and 16590, KIT and IDBG-642326 and ENSBTAG00000002699 and 280832
Gene info
MeSH Data
  • Name
  • Concept
    Scope note: The number of CD4-POSITIVE T-LYMPHOCYTES per unit volume of BLOOD. Determination requires the use of a fluorescence-activated flow cytometer.
  • Tree numbers
    • E01.370.225.500.195.107.595.500.150
    • E01.370.225.625.107.595.500.150
    • E05.200.500.195.107.595.500.150
    • E05.200.625.107.595.500.150
    • E05.242.195.107.595.500.150
  • Qualifiers
    ethics, trends, veterinary, history, classification, economics, instrumentation, methods, standards, statistics & numerical data
Product images
Similar products
Filters
Contact
Chat with gentaur.com employee