EpCAM Antibody FITC-Conjugated

  • Catalog number
    MBS5400032
  • Price
    Please ask
  • Size
    0,1 mg FITC
  • Other size
    please contact us to order other different size
  • Properties
    If you buy Antibodies supplied by MyBioSource they should be stored frozen at - 24°C for long term storage and for short term at + 5°C. This MyBioSource Fluorescein isothiocyanate (FITC) antibody is currently after some BD antibodies the most commonly used fluorescent dye for FACS. When excited at 488 nanometers, FITC has a green emission that's usually collected at 530 nanometers, the FL1 detector of a FACSCalibur or FACScan. FITC has a high quantum yield (efficiency of energy transfer from absorption to emission fluorescence) and approximately half of the absorbed photons are emitted as fluorescent light. For fluorescent microscopy applications, the 1 FITC is seldom used as it photo bleaches rather quickly though in flow cytometry applications, its photo bleaching effects are not observed due to a very brief interaction at the laser intercept. MyBioSource FITC is highly sensitive to pH extremes.
  • Conjugation
    Anti-FITC Antibody
  • French translation
    anticorps
  • Gene target
  • Short name
    EpCAM Antibody FITC-Conjugated
  • Technique
    Antibody, FITC, antibodies against human proteins, antibodies for, antibody Conjugates, Fluorescein
  • Label
    FITC
  • Alternative name
    epithelial cellular adhesion molecule (antibody to-) fluorecein-coupled
  • Alternative technique
    antibodies, fluorescine
  • Alternative to gene target
    epithelial cell adhesion molecule, DIAR5 and EGP-2 and EGP314 and EGP40 and ESA and HNPCC8 and KS1/4 and KSA and M4S1 and MIC18 and MK-1 and TACSTD1 and TROP1, EPCAM and IDBG-50831 and ENSG00000119888 and 4072, protein complex binding, Cell surfaces, Epcam and IDBG-201437 and ENSMUSG00000045394 and 17075, EPCAM and IDBG-633617 and ENSBTAG00000006474 and 514039
MeSH Data
  • Name
  • Concept
    Scope note: Test for tissue antigen using either a direct method, by conjugation of antibody with fluorescent dye (FLUORESCENT ANTIBODY TECHNIQUE, DIRECT) or an indirect method, by formation of antigen-antibody complex which is then labeled with fluorescein-conjugated anti-immunoglobulin antibody (FLUORESCENT ANTIBODY TECHNIQUE, INDIRECT). The tissue is then examined by fluorescence microscopy.
  • Tree numbers
    • E01.370.225.500.607.512.240
    • E01.370.225.750.551.512.240
    • E05.200.500.607.512.240
    • E05.200.750.551.512.240
    • E05.478.583.375
  • Qualifiers
    ethics, trends, veterinary, history, classification, economics, instrumentation, methods, standards, statistics & numerical data
Similar products
Filters
Contact
Chat with gentaur.com employee