anti-human CD81-FITC
-
Catalog numberMBS666718
-
PricePlease ask
-
Size120 Tests
-
-
Products_typeAntibody
-
Products_short_name[CD81]
-
Products_name_syn[Monoclonal anti-human CD81 (TAPA-1)/FITC]
-
Other_names[CD81 antigen isoform 2; CD81 antigen; CD81 antigen; tspan-28; tetraspanin-28; 26 kDa cell surface protein TAPA-1; CD81 antigen (target of antiproliferative antibody 1); CD81 molecule; 26 kDa cell surface protein TAPA-1; Target of the antiproliferative antibody 1; Tetraspanin-28; Tspan-28; CD_antigen: CD81]
-
Products_gene_name[CD81]
-
Other_gene_names[CD81; CD81; S5.7; CVID6; TAPA1; TSPAN28; TAPA1; TSPAN28; Tspan-28]
-
ClonalityMonoclonal
-
Clone[1.3.3.22]
-
ReactivityHuman
-
Form50 mM Sodium Phosphate pH 7.5, 100 mM Potassium Chloride, 150mM NaCl, 5% Glycerol, 0.2% BSA.
-
ConcentrationVolume: 0.2ml
-
Storage_stabilityStore at 2 - 5 degree C. Freeze/Thawing is not recommended. Product should retain activity for at least 12 months after shipping date when stored as recommended.
-
Tested_applicationFlow Cytometry (FC/FACS), Western Blot (WB)
-
DescriptionThis antibody needs to be stored at + 4°C in a fridge short term in a concentrated dilution. Freeze thaw will destroy a percentage in every cycle and should be avoided. Antibody for research use.
-
TestMyBioSource supplies antibodies that are for research of human proteins.
-
PropertiesThis MyBioSource Fluorescein isothiocyanate (FITC) antibody is currently after some BD antibodies the most commonly used fluorescent dye for FACS. When excited at 488 nanometers, FITC has a green emission that's usually collected at 530 nanometers, the FL1 detector of a FACSCalibur or FACScan. FITC has a high quantum yield (efficiency of energy transfer from absorption to emission fluorescence) and approximately half of the absorbed photons are emitted as fluorescent light. For fluorescent microscopy applications, the 1 FITC is seldom used as it photo bleaches rather quickly though in flow cytometry applications, its photo bleaching effects are not observed due to a very brief interaction at the laser intercept. MyBioSource FITC is highly sensitive to pH extremes. Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
-
ConjugationAnti-FITC Antibody
-
Gene target
-
Gene symbolCD81-AS1, CD81
-
Short nameanti- CD81-FITC
-
Techniqueanti-Human, anti-, anti, FITC, antibody to, antibodies, antibodies against human proteins, Fluorescein
-
HostMouse
-
IsotypeIgG1
-
LabelFITC
-
SpeciesHuman, Humans
-
Alternative nameAntibody tohuman CD81 molecule-fluorecein
-
Alternative techniqueantibodies, fluorescine
-
Alternative to gene targetCD81 molecule, CVID6 and S5.7 and TAPA1 and TSPAN28, CD81 and IDBG-22455 and ENSG00000110651 and 975, MHC class II protein complex binding, Cell surfaces, Cd81 and IDBG-212677 and ENSMUSG00000037706 and 12520, CD81 and IDBG-645214 and ENSBTAG00000047495 and 511435
-
Gene info
-
Identity
-
Gene
-
Long gene nameCD81 antisense RNA 1
-
GenBank acession
-
Locus
-
Discovery year2013-10-18
-
Entrez gene record
-
Classification
- Antisense RNAs
-
VEGA ID
Gene info
-
Identity
-
Gene
-
Long gene nameCD81 molecule
-
Synonyms gene
-
Synonyms gene name
- CD81 antigen (target of antiproliferative antibody 1)
-
Synonyms
-
Locus
-
Discovery year1992-10-21
-
Entrez gene record
-
Pubmed identfication
-
RefSeq identity
-
Classification
- Tetraspanins
- CD molecules
-
VEGA ID
-
Locus Specific Databases
MeSH Data
-
Name
-
ConceptScope note: Test for tissue antigen using either a direct method, by conjugation of antibody with fluorescent dye (FLUORESCENT ANTIBODY TECHNIQUE, DIRECT) or an indirect method, by formation of antigen-antibody complex which is then labeled with fluorescein-conjugated anti-immunoglobulin antibody (FLUORESCENT ANTIBODY TECHNIQUE, INDIRECT). The tissue is then examined by fluorescence microscopy.
-
Tree numbers
- E01.370.225.500.607.512.240
- E01.370.225.750.551.512.240
- E05.200.500.607.512.240
- E05.200.750.551.512.240
- E05.478.583.375
-
Qualifiersethics, trends, veterinary, history, classification, economics, instrumentation, methods, standards, statistics & numerical data