Verified reactivity
Homo sapiens (Human)
-
Detection limits
Please contact us
-
Sensitivity limit
Please contact us
-
Samples to be analyzed
Tissue homogenates, cell lysates and other biological fluids
-
Assay duration
2 hours, 30min
-
Verified applications
CLIA
-
Assay class
Sandwich
-
ELISA detection
Chemiluminescent
-
Protein number
Please refer to Uniprot
-
Alternate protein number
Please refer to SwissProt
-
Gene number
Please refer to GenBank
-
Gene name
Albumin
-
Alternate gene name
Serum albumin
-
Estimated production time
7-11 business days
-
Shipping requirements
Blue ice
-
Storage recommendation
-20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Use for
8 months
-
ELISA s specificity
This assay has high sensitivity and excellent specificity for detection of Albumin (ALB). No significant cross-reactivity or interference between Albumin (ALB) and analogues was observed.
-
ELISA s cross reactivity
This assay doesn't seem to cross-react with other species. For more information about cross-reactivity please contact us.
-
Assay principle
The microplate provided in this kit has been pre-coated with an antibody specific to Albumin (ALB). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Albumin (ALB). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Albumin (ALB) level in the sample or standard.;
-
Protocol
Please see ELISA's datasheet, otherwise contact us
-
Precision of the test
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Albumin (ALB) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Albumin (ALB) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV
-
ELISA s stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
-
QC
The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
-
Research main area
Tumor immunity;Infection immunity;Hematology;Hepatology;Nutrition metabolism;
-
Warnings
Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Notes
For research use only. Not for diagnostic procedures.
-
-
Description
This antibody needs to be stored at + 4°C in a fridge short term in a concentrated dilution. Freeze thaw will destroy a percentage in every cycle and should be avoided. Antibody for research use. A microtiter plate (spelled Microtiter is a registered trade name in the United States) or microplate or micro well plate or multiwell, is a flat plate with multiple "wells" used as small test tubes. The microplate has become a standard tool in analytical research and clinical diagnostic testing laboratories. A very common usage is in the enzyme-linked immunosorbent assay (ELISA), the basis of most modern medical diagnostic testing in humans and animals.
A microplate typically has 6, 24, 96, 384 or 1536 sample wells arranged in a 23 rectangular matrix. Some microplates have even been manufactured with 3456 or 9600 wells, and an "array tape" product has been developed that provides a continuous strip of microplates embossed on a flexible plastic tape.
-
Properties
If you buy Antibodies supplied by bioma they should be stored frozen at - 24°C for long term storage and for short term at + 5°C. Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
-
French translation
anticorps
-
Gene target
-
Gene symbol
ALB, FBF1
-
Short name
Anti-Albumin Antibody (Anti-ALB) CLIA Kit, 96
-
Technique
Antibody, anti-, anti, antibody to, antibodies, antibodies against human proteins, antibodies for
-
Species
Human, Humans
-
Alternative name
H. sapiens Antibody toAlbumin (antibody to-) (Antibody toALB) CLIA reagent, 96 well plate
-
Alternative technique
antibodies, kits
-
Alternative to gene target
v-kit Hardy-Zuckerman 4 feline sarcoma viral oncogene homolog, C-Kit and CD117 and PBT and SCFR, KIT and IDBG-18980 and ENSG00000157404 and 3815, transferase activity, Extracellular, Kit and IDBG-172083 and ENSMUSG00000005672 and 16590, KIT and IDBG-642326 and ENSBTAG00000002699 and 280832
-