CD4-PERCP

  • Catalog number
    CD4--GMS100H
  • Price
    Please ask
  • Size
    100 tests
  • Product type
    Antibody
  • Clone
    EDU-2
  • Format
    PERCP
  • Size 2
    1ml
  • Target Species
    anti Human
  • Reg
    CE-IVD
  • Description
    CD4+ T helper cell marker or cluster differentiator of white blood cells in FACS or flow cytometry. Used offer coupled to magnetic beads. GENTAUR makes custom magnetic bead couplings on 50 and 250 nm beads for certain clones.
  • Conjugate
    Peridinin chlorophyll (PerCP)
  • Gene target
    CD4  
  • Gene symbol
    CD4
  • Short name
    CD4-PERCP
  • Technique
    Percp, Peridinin chlorophyll protein (PerCP) has a 677 nanometer maximum emission, red, when excited at 488 nanometers and the CD4-PERCP is detected on the FL3 detector of a FACSCalibur or FACScan. A PerCP dye is also available (PerCP-Cy5.5, also written Cy5.5-PerCP). PerCP is not suited for the high-powered lasing (>150mW) applications, such as on a MoFlo, due to it photobleaching (features/ qualities/ traits). PerCP conjugates can only be received/be gotten from the Becton Dickinson/Pharmingen group of companies or from AcZon.
  • Isotype
    Ms IgG2a
  • Label
    PerCP
  • Alternative name
    CD4 molecule-PERCP
  • Alternative technique
    antibodies-percp
  • Alternative to gene target
    CD4 molecule, CD4mut, CD4 and IDBG-15034 and ENSG00000010610 and 920, protein homodimerization activity, Cell surfaces, Cd4 and IDBG-188351 and ENSMUSG00000023274 and 12504, CD4 and IDBG-640247 and ENSBTAG00000003255 and 407098
Gene info
  • Identity
  • Gene
    CD4
  • Long gene name
    CD4 molecule
  • Synonyms gene name
    • CD4 antigen (p55)
    • T-cell surface glycoprotein CD4
  • GenBank acession
  • Locus
  • Discovery year
    1986-01-01
  • Entrez gene record
    920
  • RefSeq identity
  • Classification
    • CD molecules
    • C2-set domain containing
    • V-set domain containing
  • VEGA ID
MeSH Data
  • Name
  • Concept
    Scope note: The number of CD4-POSITIVE T-LYMPHOCYTES per unit volume of BLOOD. Determination requires the use of a fluorescence-activated flow cytometer.
  • Tree numbers
    • E01.370.225.500.195.107.595.500.150
    • E01.370.225.625.107.595.500.150
    • E05.200.500.195.107.595.500.150
    • E05.200.625.107.595.500.150
    • E05.242.195.107.595.500.150
  • Qualifiers
    ethics, trends, veterinary, history, classification, economics, instrumentation, methods, standards, statistics & numerical data