Human Serine Palmitoyltransferase, Long Chain Base Subunit 3 (SPTLC3) ELISA Kit, 96 well plate

  • Catalog number
    EKU07283
  • Price
    Please ask
  • Size
    96T
  • Verified reactivity
    Homo sapiens (Human)
  • Detection limits
    0.156-10 ng/mL
  • Sensitivity limit
    0,059 ng/mL
  • Samples to be analyzed
    Tissue homogenates and other biological fluids.
  • Assay duration
    3 hours
  • Verified applications
    ELISA
  • Assay class
    Sandwich
  • ELISA detection
    Colorimetric
  • Protein number
    Q9NUV7
  • Alternate protein number
    Please refer to SwissProt
  • Gene number
    55304
  • Gene name
    Serine Palmitoyltransferase, Long Chain Base Subunit 3
  • Alternate gene name
    SPTLC2L; SPT 3; LCB 3; C20orf38; Aminotransferase 2; Serine-palmitoyl-CoA transferase 3; Long chain base biosynthesis protein 3
  • Estimated production time
    7-11 business days
  • Shipping requirements
    Blue ice
  • Storage recommendation
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
  • Use for
    8 months
  • ELISA s specificity
    This assay has high sensitivity and excellent specificity for detection of Serine Palmitoyltransferase, Long Chain Base Subunit 3 (SPTLC3). No significant cross-reactivity or interference between Serine Palmitoyltransferase, Long Chain Base Subunit 3 (SPTLC3) and analogues was observed.
  • ELISA s cross reactivity
    This assay doesn't seem to cross-react with other species. For more information about cross-reactivity please contact us.
  • Assay principle
    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Serine Palmitoyltransferase, Long Chain Base Subunit 3 (SPTLC3). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Serine Palmitoyltransferase, Long Chain Base Subunit 3 (SPTLC3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Serine Palmitoyltransferase, Long Chain Base Subunit 3 (SPTLC3), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Serine Palmitoyltransferase, Long Chain Base Subunit 3 (SPTLC3) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
  • Protocol
    Please see ELISA's datasheet, otherwise contact us
  • Precision of the test
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Serine Palmitoyltransferase, Long Chain Base Subunit 3 (SPTLC3) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Serine Palmitoyltransferase, Long Chain Base Subunit 3 (SPTLC3) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV
  • ELISA s stability
    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
  • QC
    The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
  • Research main area
    Enzyme & Kinase;
  • Warnings
    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
  • Notes
    For research use only. Not for diagnostic procedures.
  • Properties
    E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
  • Test
    ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
  • Description
    A microtiter plate (spelled Microtiter is a registered trade name in the United States) or microplate or micro well plate or multiwell, is a flat plate with multiple "wells" used as small test tubes. The microplate has become a standard tool in analytical research and clinical diagnostic testing laboratories. A very common usage is in the enzyme-linked immunosorbent assay (ELISA), the basis of most modern medical diagnostic testing in humans and animals. A microplate typically has 6, 24, 96, 384 or 1536 sample wells arranged in a 23 rectangular matrix. Some microplates have even been manufactured with 3456 or 9600 wells, and an "array tape" product has been developed that provides a continuous strip of microplates embossed on a flexible plastic tape. Serine protease, D- or L-serine arginine rich enzyme of serine threonine kinase with serine that is encoded by the codons UCU, UCC, UCA, UCG, AGU and AGC is an ɑ-amino acid that is used in the biosynthesis of proteins. It contains an α-amino group (which is in the protonated −NH+ 3 form under biological conditions), a carboxyl group. It is non-essential in humans, meaning the body can synthesize it.
  • Gene target
  • Gene symbol
    SPTLC3
  • Short name
    Serine Palmitoyltransferase, Long Chain Base Subunit 3 (SPTLC3) ELISA Kit, 96
  • Technique
    ELISA kit, ELISA, ELISAs Enzyme-linked immunosorbent assay 90320007 SNOMED code are used by the medical researcher for detection of human, mouse, … proteins are supplied in coated 96 well plates to be stored at +4°C. ELISA test kits can be sandwich ELISA. In sandwich ELISAS Enzyme-linked immunosorbent assay 9we use captor and detector antibodies. In single antibody ELISAs the antigen is coated and only a detector antibody is used. Traditional competition antigen ELISAs are coated with a captor antibody and a competitive antigen is labelled with the chromogen. In this case the ratio on your graph will be inverse proportional with the antigen present in your sample. A sign detected by the Colorimetric detection OD optical density absorbance at 450 nm between 0 and 4 with an ELISA reader for 450 nm absortion. Genprice Inc. the recognized authority tax ID 45-4304622 D-U-N-S number - 078440800. MeSH code E05 478 566 350 170 Enzyme-Linked Immunosorbent Assay. PROMT code 3841327 Immunoabsorbent assay tests. ELISA tests are enzyme linked immunoassays to detect human, mouse or other proteins in serum, plasma, urine or biological fluids. MeSH code E05 478 566 350 170 for Enzyme-Linked Immunosorbent Assay or ELISA kits. Also Enzyme-linked immunoassay, competitive have the SNOMED name 61461007 and the PROMT code for ELISA readers is 3841330. This is the desigation of other diagnostic analyzers and tests.
  • Host
    antigen assay ELISA kit 1 Kit (96 Wells)
  • Species
    Human, Humans
  • Alternative name
    H. sapiens Serine Palmitoyltransferase, large epitope Base functionnal sequence 3 (SPTLC3) Enzyme-linked immunosorbent assay reagent, 96 well plate
  • Alternative technique
    elisas, kits
  • Alternative to gene target
    v-kit Hardy-Zuckerman 4 feline sarcoma viral oncogene homolog, C-Kit and CD117 and PBT and SCFR, KIT and IDBG-18980 and ENSG00000157404 and 3815, transferase activity, Extracellular, Kit and IDBG-172083 and ENSMUSG00000005672 and 16590, KIT and IDBG-642326 and ENSBTAG00000002699 and 280832
Gene info
MeSH Data
  • Name
  • Concept
    Scope note: An immunoassay utilizing an antibody labeled with an enzyme marker such as horseradish peroxidase. While either the enzyme or the antibody is bound to an immunosorbent substrate, they both retain their biologic activity; the change in enzyme activity as a result of the enzyme-antibody-antigen reaction is proportional to the concentration of the antigen and can be measured spectrophotometrically or with the naked eye. Many variations of the method have been developed.
  • Tree numbers
    • E05.478.566.350.170
    • E05.478.566.380.360
    • E05.478.583.400.170
    • E05.601.470.350.170
    • E05.601.470.380.360
  • Qualifiers
    ethics, mortality, psychology, trends, veterinary, history, classification, economics, instrumentation, methods, nursing, standards, adverse effects, statistics & numerical data
Product images
Similar products
Filters
Contact
Chat with gentaur.com employee