Verified reactivity
Homo sapiens (Human)
-
Detection limits
31.25-2000 pg/mL
-
Sensitivity limit
1,36 pg/mL
-
Samples to be analyzed
Serum, plasma, urine and other biological fluids
-
Assay duration
2 hours, 40min
-
Verified applications
CLIA
-
Assay class
Sandwich
-
ELISA detection
Chemiluminescent
-
Protein number
P02760
-
Alternate protein number
Please refer to SwissProt
-
Gene number
259
-
Gene name
Alpha-1-Microglobulin/Bikunin Precursor
-
Alternate gene name
AMBP; UTI; HCP; EDC1; HI30; IATIL; ITILC; ITI; ITIL; Alpha 1 Microglobulin/Bikunin Precursor; Growth-inhibiting protein 19; Uristatin; Uronic-Acid-Rich Protein; Trypstatin
-
Estimated production time
7-11 business days
-
Shipping requirements
Blue ice
-
Storage recommendation
-20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Use for
8 months
-
ELISA s specificity
This assay has high sensitivity and excellent specificity for detection of Alpha-1-Microglobulin/Bikunin Precursor (a1M). No significant cross-reactivity or interference between Alpha-1-Microglobulin/Bikunin Precursor (a1M) and analogues was observed.
-
ELISA s cross reactivity
This assay doesn't seem to cross-react with other species. For more information about cross-reactivity please contact us.
-
Assay principle
The microplate provided in this kit has been pre-coated with an antibody specific to Alpha-1-Microglobulin/Bikunin Precursor (a1M). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Alpha-1-Microglobulin/Bikunin Precursor (a1M). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Alpha-1-Microglobulin/Bikunin Precursor (a1M) level in the sample or standard.;
-
Protocol
Please see ELISA's datasheet, otherwise contact us
-
Precision of the test
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Alpha-1-Microglobulin/Bikunin Precursor (a1M) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Alpha-1-Microglobulin/Bikunin Precursor (a1M) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV
-
ELISA s stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
-
QC
The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
-
Research main area
Infection immunity;Immune molecule;Kidney biomarker;
-
Warnings
Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Notes
For research use only. Not for diagnostic procedures.
-
-
Description
The Alpha-1-Microglobulin/Bikunin (a1M) CLIA Kit, 96 is a α- or alpha protein sometimes glycoprotein present in blood. A microtiter plate (spelled Microtiter is a registered trade name in the United States) or microplate or micro well plate or multiwell, is a flat plate with multiple "wells" used as small test tubes. The microplate has become a standard tool in analytical research and clinical diagnostic testing laboratories. A very common usage is in the enzyme-linked immunosorbent assay (ELISA), the basis of most modern medical diagnostic testing in humans and animals.
A microplate typically has 6, 24, 96, 384 or 1536 sample wells arranged in a 23 rectangular matrix. Some microplates have even been manufactured with 3456 or 9600 wells, and an "array tape" product has been developed that provides a continuous strip of microplates embossed on a flexible plastic tape. Precursor cell, also called a blast cell or simply blast, is a type of partially differentiated, usually unipotent cell that has lost most or all of the stem cell multipotency.
-
Properties
Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
-
Gene target
-
Gene symbol
IGHVII-1-1, MIR1-1, TRUND-NNN8-1, TRUND-NNN7-1, IGKV1OR2-1, MIR101-1, MIR1289-1, MIR16-1, PIRC1
-
Short name
Alpha-1-Microglobulin/Bikunin (a1M) CLIA Kit, 96
-
Species
Human, Humans
-
Alternative name
H. sapiens a-1-Microglobulin/Bikunin Precursor (a1M) CLIA reagent, 96 well plate
-
Alternative technique
kits
-
Alternative to gene target
v-kit Hardy-Zuckerman 4 feline sarcoma viral oncogene homolog, C-Kit and CD117 and PBT and SCFR, KIT and IDBG-18980 and ENSG00000157404 and 3815, transferase activity, Extracellular, Kit and IDBG-172083 and ENSMUSG00000005672 and 16590, KIT and IDBG-642326 and ENSBTAG00000002699 and 280832
-