Thyroid Peroxidase [TPO] IgG (human) ELISA Kit

  • Catalog number
    K5351-100
  • Price
    Please ask
  • Size
    100 assays
  • Description
    Sensitive, Colorimetric Assay
  • Summary
    • Detection method- Absorbance (450 nm) • Species reactivity-human • Application- Detection of IgG Ab to TPO
  • Detection Method
    Absorbance (450 nm)
  • Species Reactivity
    human
  • Applications
    This ELISA kit is used for detection of IgG Ab to TPO
  • Sample Type
    Serum or plasma
  • Features Benefits
    • Easy, convenient and time-saving method to detect TPO IgG in human serum or plasma.
  • Storage Conditions
    2-8°C
  • Shipping Conditions
    gel pack
  • Shelf life
    24 months
  • Background
    Thyroid peroxidase (TPO) is the major autoantigen (933 amino acid residue) in the thyroid microsomal antigen (TMA) particle. Detection of TPO antibodies is strong evidence against a goiter or non-autoimmune causes of hypothyroidism. The annual risk for the development of hypothyroidism is 3% to 4% per year if TPO antibodies are present and TSH is elevated. TPO antibodies are present in 8-9% normal controls, 57-74% patients with Graves disease, 99-100% of Hashimoto disease or idiopathic myxedema, 19% with differentiated thyroid cancer, and 11% of those with other miscellaneous non-autoimmune thyroid diseases. The prevalence of positive TPO antibodies is higher in elderly (mean age 80 years) women (10%) compared to elderly men (2%).Autoantibody concentration in centenarians also decreases. Studies of TPO epitopes in each domain, A and B, and detection of their specific autoantibodies suggest that the epitope-specific TPO antibodies ratio (A/B) does not change over time in individual patients and that TPO epitope autoantibody patterns may be inherited. In BioVision’s TPO IgG ELISA Kit, sample is added to the wells coated with purified TPO recombinant antigen. TPO IgG specific antibody, if present, binds to the antigen. All unbound materials are washed away and the enzyme conjugate is added to bind to the antibody-antigen complex, if present. Excess enzyme conjugate is washed off and substrate is added. The plate is incubated to allow the hydrolysis of the substrate by the enzyme. The intensity of the color generated is proportional to the amount of IgG specific antibody in the sample.
  • Properties
    E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
  • Test
    ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
  • About
    Immunoglobulin gamma, IgG, mouse monoclonal H&L chain clones or rabbit, goat polyclonal antibodies have 4 parts. There are 2 heavy chains, 2 light chains. The IgG antibody has 2 antigen binding sites. They represent 70% or more of serum antibodies. This antibody can be antigen purified or protein A or G purified. For storage sodium azide is added or you can call us to request azide free antibody preparations. These will need colder storage temperatures.
  • Conjugate
    Peroxidases with EC number 1.11.1.x are catalyzing the reaction of ROOR' + electron donor (2 e−) + 2H+ → ROH + R'OH
  • Gene target
    Thyroid   [TPO]  
  • Gene symbol
    TPO, THPO
  • Short name
    Thyroid [TPO] IgG ( ) ELISA Kit
  • Technique
    ELISA kit, ELISA, IgG, ELISAs Enzyme-linked immunosorbent assay 90320007 SNOMED code are used by the medical researcher for detection of human, mouse, … proteins are supplied in coated 96 well plates to be stored at +4°C. ELISA test kits can be sandwich ELISA. In sandwich ELISAS Enzyme-linked immunosorbent assay 9we use captor and detector antibodies. In single antibody ELISAs the antigen is coated and only a detector antibody is used. Traditional competition antigen ELISAs are coated with a captor antibody and a competitive antigen is labelled with the chromogen. In this case the ratio on your graph will be inverse proportional with the antigen present in your sample. A sign detected by the Colorimetric detection OD optical density absorbance at 450 nm between 0 and 4 with an ELISA reader for 450 nm absortion. Genprice Inc. the recognized authority tax ID 45-4304622 D-U-N-S number - 078440800. MeSH code E05 478 566 350 170 Enzyme-Linked Immunosorbent Assay. PROMT code 3841327 Immunoabsorbent assay tests. ELISA tests are enzyme linked immunoassays to detect human, mouse or other proteins in serum, plasma, urine or biological fluids. MeSH code E05 478 566 350 170 for Enzyme-Linked Immunosorbent Assay or ELISA kits. Also Enzyme-linked immunoassay, competitive have the SNOMED name 61461007 and the PROMT code for ELISA readers is 3841330. This is the desigation of other diagnostic analyzers and tests. IgGs
  • Host
    antigen assay ELISA kit 1 Kit (96 Wells)
  • Isotype
    IgG, IgG
  • Label
    peroxidase
  • Species
    Human, Humans
  • Alternative name
    Thyroid Peroxidase [TPO] Immunoglobulin G (H. sapiens) Enzyme-linked immunosorbent assay reagent
  • Alternative technique
    elisas, kits, immunoglobulins
  • Alternative to gene target
    v-kit Hardy-Zuckerman 4 feline sarcoma viral oncogene homolog, C-Kit and CD117 and PBT and SCFR, KIT and IDBG-18980 and ENSG00000157404 and 3815, transferase activity, Extracellular, Kit and IDBG-172083 and ENSMUSG00000005672 and 16590, KIT and IDBG-642326 and ENSBTAG00000002699 and 280832
  • Tissue
    thyroid
Gene info
Gene info
MeSH Data
  • Name
  • Concept
    Scope note: An immunoassay utilizing an antibody labeled with an enzyme marker such as horseradish peroxidase. While either the enzyme or the antibody is bound to an immunosorbent substrate, they both retain their biologic activity; the change in enzyme activity as a result of the enzyme-antibody-antigen reaction is proportional to the concentration of the antigen and can be measured spectrophotometrically or with the naked eye. Many variations of the method have been developed.
  • Tree numbers
    • E05.478.566.350.170
    • E05.478.566.380.360
    • E05.478.583.400.170
    • E05.601.470.350.170
    • E05.601.470.380.360
  • Qualifiers
    ethics, mortality, psychology, trends, veterinary, history, classification, economics, instrumentation, methods, nursing, standards, adverse effects, statistics & numerical data
Product images
Similar products
Filters
Contact
Chat with gentaur.com employee