Verified reactivity
Oryctolagus cuniculus (Rabbit)
-
Detection limits
3.12-200 pg/mL
-
Sensitivity limit
1,19 pg/mL
-
Samples to be analyzed
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
-
Assay duration
3 hours
-
Verified applications
ELISA
-
Assay class
Sandwich
-
ELISA detection
Colorimetric
-
Protein number
Q9MZR1
-
Alternate protein number
Please refer to SwissProt
-
Gene number
100008733
-
Gene name
Interleukin 6
-
Alternate gene name
MGI2-A; MGI2A; HGF; BSF2; HSF; IFNB2; B-Cell Stimulatory Factor-2; Hybridoma/Plasmacytoma Growth Factor; Hepatocyte Stimulating Factor; Cytotoxic T-Cell Differentiation Factor
-
Estimated production time
7-11 business days
-
Shipping requirements
Blue ice
-
Storage recommendation
-20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Use for
8 months
-
ELISA s specificity
This assay has high sensitivity and excellent specificity for detection of Interleukin 6 (IL6). No significant cross-reactivity or interference between Interleukin 6 (IL6) and analogues was observed.
-
ELISA s cross reactivity
This assay doesn't seem to cross-react with other species. For more information about cross-reactivity please contact us.
-
Assay principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Interleukin 6 (IL6). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Interleukin 6 (IL6). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Interleukin 6 (IL6), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Interleukin 6 (IL6) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
-
Protocol
Please see ELISA's datasheet, otherwise contact us
-
Precision of the test
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 6 (IL6) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 6 (IL6) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV
-
ELISA s stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
-
QC
The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
-
Research main area
Cytokine;Tumor immunity;Infection immunity;Cardiovascular biology;
-
Warnings
The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Notes
For research use only. Not for diagnostic procedures.
-
-
Properties
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays
-
Test
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
-
Gene
Interleukin 6 (IL-6) is an interleukin that acts as both a pro-inflammatory cytokine and an anti-inflammatory myokine. In humans, it is encoded by the IL6 gene. Recombinant, rec. E. coli interleukin-6 for cell culture or antibody production.
-
Description
A microtiter plate (spelled Microtiter is a registered trade name in the United States) or microplate or micro well plate or multiwell, is a flat plate with multiple "wells" used as small test tubes. The microplate has become a standard tool in analytical research and clinical diagnostic testing laboratories. A very common usage is in the enzyme-linked immunosorbent assay (ELISA), the basis of most modern medical diagnostic testing in humans and animals.
A microplate typically has 6, 24, 96, 384 or 1536 sample wells arranged in a 23 rectangular matrix. Some microplates have even been manufactured with 3456 or 9600 wells, and an "array tape" product has been developed that provides a continuous strip of microplates embossed on a flexible plastic tape.
-
About
Rabbits are used for polyclonal antibody production by bioma. Rabbit antibodies are very stable and can be stored for several days at room temperature. bioma adds sodium azide and glycerol to enhance the stability of the rabbit polyclonal antibodies. Anti-human, anti mouse antibodies to highly immunogenic selected peptide sequences are" monoclonal like" since the epitope to which they are directed is less than 35 amino acids long.
-
Latin name
Oryctolagus cuniculus
-
Gene target
-
Gene symbol
IL6-AS1, IL6, CEBPD
-
Short name
Rabbit Interleukin 6 (IL6) ELISA Kit, 96
-
Technique
ELISA kit, Rabbit, ELISA, ELISAs Enzyme-linked immunosorbent assay 90320007 SNOMED code are used by the medical researcher for detection of human, mouse, … proteins are supplied in coated 96 well plates to be stored at +4°C. ELISA test kits can be sandwich ELISA. In sandwich ELISAS Enzyme-linked immunosorbent assay 9we use captor and detector antibodies. In single antibody ELISAs the antigen is coated and only a detector antibody is used. Traditional competition antigen ELISAs are coated with a captor antibody and a competitive antigen is labelled with the chromogen. In this case the ratio on your graph will be inverse proportional with the antigen present in your sample. A sign detected by the Colorimetric detection OD optical density absorbance at 450 nm between 0 and 4 with an ELISA reader for 450 nm absortion. Genprice Inc. the recognized authority tax ID 45-4304622 D-U-N-S number - 078440800. MeSH code E05 478 566 350 170 Enzyme-Linked Immunosorbent Assay. PROMT code 3841327 Immunoabsorbent assay tests. ELISA tests are enzyme linked immunoassays to detect human, mouse or other proteins in serum, plasma, urine or biological fluids. MeSH code E05 478 566 350 170 for Enzyme-Linked Immunosorbent Assay or ELISA kits. Also Enzyme-linked immunoassay, competitive have the SNOMED name 61461007 and the PROMT code for ELISA readers is 3841330. This is the desigation of other diagnostic analyzers and tests.
-
Host
Rabbit, antigen assay ELISA kit 1 Kit (96 Wells), Rabbits
-
Alternative name
production species: rabbit Interleukin 6 (interleukin 6 (interferon, beta 2)) Enzyme-linked immunosorbent assay reagent, 96 well plate
-
Alternative technique
rabbit-anti, elisas, kits
-
Alternative to gene target
interleukin 6 (interferon, beta 2), BSF2 and HGF and HSF and IFNB2 and IL-6, IL6 and IDBG-9462 and ENSG00000136244 and 3569, growth factor activity, Extracellular, Il6 and IDBG-144970 and ENSMUSG00000025746 and 16193, IL6 and IDBG-630280 and ENSBTAG00000014921 and 280826
-