Description
Cell Meter Intracellular Fluorimetric Hydrogen Peroxide Assay Kit *Blue Fluorescence Optimized for Flow Cytometry* is a kit that uses our uniqu OxiVision Blue peroxide sensor to quantify hydrogen peroxide in live cells. OxiVision Blue peroxide sensor is cell-permeable, and generates blue fluorescence when it reacts with hydrogen peroxide. This kit provides a sensitive tool to monitor hydrogen peroxide level in living cells, and it is optimized to be used in flow cytometry.
-
-
Shipping
Blue Ice
-
Storage
Freezer
-
Shelflife
6 months
-
Chemical Components
Component A: OxiVision™ Blue peroxide sensor ; Component B: Assay Buffer; Component C: DMSO
-
Excitation Wavelength
405 nm
-
Emission Wavelength
450 nm
-
Personal precautions
Use appropriate protective equipment and methods to clean up spilled substances promptly.
-
Uses
Laboratory chemicals *For Research Use Only*
-
-
-
Ordering
To order Cell Meter Intracellular Fluorimetric Hydrogen Peroxide Assay Kit *Blue Fluorescence Optimized for Flow Cytometry*, please use the Cat. Nr.11505 and submit your purchase order by email or by fax. A discount is available for larger or bulk quantities, please contact us for more information
-
Tips
Our specialists recommend you to follow carefully the pre-registered instructions for Cell Meter Intracellular Fluorimetric Hydrogen Peroxide Assay Kit *Blue Fluorescence Optimized for Flow Cytometry*
-
Test
aat supplies other types of Assays as 1. Flow cytometry uses monoclonal antibodies of specific affinity clones for cell counting, cell sorting and biomarker detection by suspending cells in a stream of fluid for Forward Scatter, FSC and side scatter, SSC analysis. Human PBMCs can be loaded with CFSE tracking dye after non adherent cell harvesting. Subsequently labeled with anti-CD antibodies, and analyzed by multiparameter flow cytometry. Two-parameter profiles of CD vs. CFSE; and another CD vs. FSC-W. We suggest to use FSC-H vs. FSC-A. FSC-A, FSC-H, FSC-W = area, height, and width of the forward 488 nm light scatter from the flow signal. Fluorimetric analysis of fluorescent emission of light by is a form of luminescence. The emitted light has a longer wavelength, and therefore lower energy, than the absorbed radiation for excitation. Fluorescent controls and calibrators can be supplied to mix with the cells. A fluorimeter is needed to do the analysis of the green, red, blue, yellow, orange, deep red fluorescent dyes.
-
Properties
Blue has a wavelength of around 480 nm and will make your sample visible. If your sample is too concentrated you can dissolve it in water.
-
Conjugation
Blue Substrate
-
Additional description
For cells, cell lines and tissues in culture till half confluency. FACS or Flow Cytometry is an SSC and FSC analysis by scattered light gating. Becton, BD or coulter facses analyze for the major part human CD marker antibodies and cellular markers by PE or FITC labelled antibodies. Facses or flow cytometers will analyze forward and side scatters by gating of human lymphocytes. Becton Dickinson uses anti human CD antigens, CD4, CD8 monoclonals. The clones of these antibodies have a known affinity to these membrane receptors.