Human HbA1c (Glycated Hemoglobin A1c) ELISA Kit

CAT:
855-ELK5487-01
Size:
48 Tests
  • Availability: 24/48H Stock Items & 2 to 6 Weeks non Stock Items.
  • Dry Ice Shipment: No
Human HbA1c (Glycated Hemoglobin A1c) ELISA Kit - image 1

Human HbA1c (Glycated Hemoglobin A1c) ELISA Kit

  • Description:

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HbA1c. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HbA1c. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HbA1c, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HbA1c in the samples is then determined by comparing the OD of the samples to the standard curve.
  • Product Name Alternative:

    Glycosylated Hemoglobin; Hemoglobin A1c; Hb1c; HbAIc; HbAIc
  • Gene Aliases:

    Glycosylated Hemoglobin; Hemoglobin A1c; Hb1c; HbAIc; HbAIc
  • Reactivity:

    Human
  • Field of Research:

    Diagnosis of diabetes mellitus
  • Assay Type:

    Sandwich
  • Assay Principle:

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HbA1c. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HbA1c. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HbA1c, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HbA1c in the samples is then determined by comparing the OD of the samples to the standard curve.
  • Assay Performance Time:

    3.5 H
  • Standard:

    200 ng/mL
  • Sample Type:

    Plasma
  • Detection Range:

    3.13 - 200 ng/mL
  • Sensitivity:

    1.31 ng/mL
  • Species:

    Human
  • CAS Number:

    7732-18-5