-
Verified reactivity
Rattus norvegicus (Rat)
-
Detection limits
123.5-10,000 pg/mL
-
Sensitivity limit
43,7 pg/mL
-
Samples to be analyzed
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
-
Assay duration
3 hours
-
Verified applications
ELISA
-
Assay class
Competitive
-
ELISA detection
Colorimetric
-
Protein number
P49000
-
Alternate protein number
Please refer to SwissProt
-
Gene number
25378
-
Gene name
Anti-Mullerian Hormone
-
Alternate gene name
MIF; MIH; MIS; Müllerian Inhibiting Factor; Müllerian Inhibiting Hormone; Müllerian Inhibiting Substance
-
Estimated production time
7-11 business days
-
Shipping requirements
Blue ice
-
Storage recommendation
-20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Use for
8 months
-
ELISA s specificity
This assay has high sensitivity and excellent specificity for detection of Anti-Mullerian Hormone (AMH). No significant cross-reactivity or interference between Anti-Mullerian Hormone (AMH) and analogues was observed.
-
ELISA s cross reactivity
This assay doesn't seem to cross-react with other species. For more information about cross-reactivity please contact us.
-
Assay principle
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Anti-Mullerian Hormone (AMH) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Anti-Mullerian Hormone (AMH) and unlabeled Anti-Mullerian Hormone (AMH) (Standards or samples) with the pre-coated antibody specific to Anti-Mullerian Hormone (AMH). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Anti-Mullerian Hormone (AMH) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Anti-Mullerian Hormone (AMH) in the sample.
-
Protocol
Please see ELISA's datasheet, otherwise contact us
-
Precision of the test
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Mullerian Hormone (AMH) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Mullerian Hormone (AMH) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV
-
ELISA s stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
-
QC
The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
-
Research main area
Endocrinology;Reproductive science;Hormone metabolism;
-
Warnings
The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Notes
For research use only. Not for diagnostic procedures.
-
-
Description
This antibody needs to be stored at + 4°C in a fridge short term in a concentrated dilution. Freeze thaw will destroy a percentage in every cycle and should be avoided. Antibody for research use. Hormone releasing factors and releasing hormones are signaling molecules produced by glands in multicellular organisms. The glands that secrete Luteinizing hormones LHRG and LH, FSH comprise the endocrine signaling system. The term growth hormone releasing hormone GHRH is sometimes extended to include chemicals produced by cells that affect the same cell (autocrine or intracrine signaling) or nearby cells (paracrine signaling). Human recombinant LHRG and GHRH are produced in E. coli or in yeast cells. A microtiter plate (spelled Microtiter is a registered trade name in the United States) or microplate or micro well plate or multiwell, is a flat plate with multiple "wells" used as small test tubes. The microplate has become a standard tool in analytical research and clinical diagnostic testing laboratories. A very common usage is in the enzyme-linked immunosorbent assay (ELISA), the basis of most modern medical diagnostic testing in humans and animals.
A microplate typically has 6, 24, 96, 384 or 1536 sample wells arranged in a 23 rectangular matrix. Some microplates have even been manufactured with 3456 or 9600 wells, and an "array tape" product has been developed that provides a continuous strip of microplates embossed on a flexible plastic tape. Low range, broad range, wide range or standard range protein kDa markers or DNA bp-kb ladders are available from bioma. ELISA kits in the standard range can be adapted to the high sensitive range only by adding some points to the lower end of the standard curve.
-
Properties
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays
-
Test
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
-
About
Rats are used to make rat monoclonal anti mouse antibodies. There are less rat- than mouse clones however. Rats genes from rodents of the genus Rattus norvegicus are often studied in vivo as a model of human genes in Sprague-Dawley or Wistar rats.
-
Latin name
Rattus norvegicus
-
Gene target
-
Gene symbol
AMH
-
Short name
Wide Anti-Mullerian Hormone (AMH) ELISA Kit, 96
-
Technique
ELISA kit, anti-, ELISA, anti, antibody to, antibodies, ELISAs Enzyme-linked immunosorbent assay 90320007 SNOMED code are used by the medical researcher for detection of human, mouse, … proteins are supplied in coated 96 well plates to be stored at +4°C. ELISA test kits can be sandwich ELISA. In sandwich ELISAS Enzyme-linked immunosorbent assay 9we use captor and detector antibodies. In single antibody ELISAs the antigen is coated and only a detector antibody is used. Traditional competition antigen ELISAs are coated with a captor antibody and a competitive antigen is labelled with the chromogen. In this case the ratio on your graph will be inverse proportional with the antigen present in your sample. A sign detected by the Colorimetric detection OD optical density absorbance at 450 nm between 0 and 4 with an ELISA reader for 450 nm absortion. Genprice Inc. the recognized authority tax ID 45-4304622 D-U-N-S number - 078440800. MeSH code E05 478 566 350 170 Enzyme-Linked Immunosorbent Assay. PROMT code 3841327 Immunoabsorbent assay tests. ELISA tests are enzyme linked immunoassays to detect human, mouse or other proteins in serum, plasma, urine or biological fluids. MeSH code E05 478 566 350 170 for Enzyme-Linked Immunosorbent Assay or ELISA kits. Also Enzyme-linked immunoassay, competitive have the SNOMED name 61461007 and the PROMT code for ELISA readers is 3841330. This is the desigation of other diagnostic analyzers and tests.
-
Host
Rat, antigen assay ELISA kit 1 Kit (96 Wells)
-
Species
Rat, Rats
-
Alternative name
Wide Range Rat Antibody toMullerian Hormone (anti-Mullerian hormone) Enzyme-linked immunosorbent assay reagent, 96 well plate
-
Alternative technique
antibodies, elisas, kits
-
Alternative to gene target
anti-Mullerian hormone, MIF and MIS, AMH and IDBG-15818 and ENSG00000104899 and 100423031,268, growth factor activity, Extracellular, Amh and IDBG-176152 and ENSMUSG00000035262 and 11705, AMH and IDBG-644611 and ENSBTAG00000014955 and 280718
-