Verified reactivity
Rabbit
-
Detection limits
0.78 ng/ml-50 ng/ml
-
Sensitivity limit
0,195 ng/ml
-
Samples to be analyzed
serum, plasma, tissue homogenates
-
Assay duration
1-5 hours
-
Verified applications
ELISA
-
Assay class
Please contact us
-
ELISA detection
Colorimetric
-
Protein number
P09601
-
Alternate protein number
Please refer to SwissProt
-
Gene number
Please refer to GenBank
-
Gene name
heme oxygenase (decycling) 1 (HMOX1)
-
Alternate gene name
Please refer to NCBI
-
Estimated production time
7-11 business days
-
Shipping requirements
Blue ice
-
Storage recommendation
-20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Use for
6 months
-
ELISA s specificity
To know the specificity of this test please feel free to contact us
-
ELISA s cross reactivity
This assay doesn't seem to cross-react with other species. For more information about cross-reactivity please contact us.
-
Assay principle
Please see ELISA's datasheet, otherwise contact us
-
Protocol
Please see ELISA's datasheet, otherwise contact us
-
Precision of the test
Please see ELISA's datasheet, otherwise contact us
-
ELISA s stability
Please see ELISA's datasheet, otherwise contact us
-
QC
The kit is manufactured at ISO 9001 certified facilities.
-
Research main area
Cardiovascular
-
Warnings
The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Notes
For research use only. Not for diagnostic procedures.
-
-
Properties
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays
-
Test
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
-
Description
A microtiter plate (spelled Microtiter is a registered trade name in the United States) or microplate or micro well plate or multiwell, is a flat plate with multiple "wells" used as small test tubes. The microplate has become a standard tool in analytical research and clinical diagnostic testing laboratories. A very common usage is in the enzyme-linked immunosorbent assay (ELISA), the basis of most modern medical diagnostic testing in humans and animals.
A microplate typically has 6, 24, 96, 384 or 1536 sample wells arranged in a 23 rectangular matrix. Some microplates have even been manufactured with 3456 or 9600 wells, and an "array tape" product has been developed that provides a continuous strip of microplates embossed on a flexible plastic tape.
-
About
Rabbits are used for polyclonal antibody production by bioma. Rabbit antibodies are very stable and can be stored for several days at room temperature. bioma adds sodium azide and glycerol to enhance the stability of the rabbit polyclonal antibodies. Anti-human, anti mouse antibodies to highly immunogenic selected peptide sequences are" monoclonal like" since the epitope to which they are directed is less than 35 amino acids long.
-
Latin name
Oryctolagus cuniculus
-
Gene target
-
Gene symbol
HMOX1
-
Short name
Rabbit heme oxygenase (decycling) 1 (HMOX1) ELISA Kit, 96
-
Technique
ELISA kit, Rabbit, ELISA, ELISAs Enzyme-linked immunosorbent assay 90320007 SNOMED code are used by the medical researcher for detection of human, mouse, … proteins are supplied in coated 96 well plates to be stored at +4°C. ELISA test kits can be sandwich ELISA. In sandwich ELISAS Enzyme-linked immunosorbent assay 9we use captor and detector antibodies. In single antibody ELISAs the antigen is coated and only a detector antibody is used. Traditional competition antigen ELISAs are coated with a captor antibody and a competitive antigen is labelled with the chromogen. In this case the ratio on your graph will be inverse proportional with the antigen present in your sample. A sign detected by the Colorimetric detection OD optical density absorbance at 450 nm between 0 and 4 with an ELISA reader for 450 nm absortion. Genprice Inc. the recognized authority tax ID 45-4304622 D-U-N-S number - 078440800. MeSH code E05 478 566 350 170 Enzyme-Linked Immunosorbent Assay. PROMT code 3841327 Immunoabsorbent assay tests. ELISA tests are enzyme linked immunoassays to detect human, mouse or other proteins in serum, plasma, urine or biological fluids. MeSH code E05 478 566 350 170 for Enzyme-Linked Immunosorbent Assay or ELISA kits. Also Enzyme-linked immunoassay, competitive have the SNOMED name 61461007 and the PROMT code for ELISA readers is 3841330. This is the desigation of other diagnostic analyzers and tests.
-
Host
Rabbit, antigen assay ELISA kit 1 Kit (96 Wells), Rabbits
-
Alternative name
production species: rabbit heme oxygenase (decycling) 1 (heme oxygenase (decycling) 1) Enzyme-linked immunosorbent assay reagent, 96 well plate
-
Alternative technique
rabbit-anti, elisas, kits
-
Alternative to gene target
heme oxygenase (decycling) 1, bK286B10 and HMOX1D and HO-1 and HSP32, HMOX1 and IDBG-5374 and ENSG00000100292 and 3162, metal ion binding, nuclei, Hmox1 and IDBG-168890 and ENSMUSG00000005413 and 15368, HMOX1 and IDBG-637915 and ENSBTAG00000015582 and 513221
-