ApoA-I antibody (FITC)

  • Catalog number
    GEN832303
  • Price
    Please ask
  • Size
    100 Tests
  • Also known as
    ApoA-I (FITC)
  • Other names
    ApoA-I; Apolipoprotein A-I; apolipoprotein A-I; apo-AI; apolipoprotein A-I; Apolipoprotein A1Cleaved into the following chain:Truncated apolipoprotein A-I; Alternative name(s):; Apolipoprotein A-I(1-242)
  • Category
    Antibodies
  • Subcategory
    Mnoclonal antibodies
  • Gene name
    ApoA-I
  • Gene name synonims
    N/A
  • Other gene names
    APOA1; APOA1; N/A; Apo-AI; ApoA-I
  • Clonality
    Monoclonal
  • Immunoglobulin isotype
    IgG2b
  • Clone
    SM1/23
  • Host organism
    Mouse (Mus musculus)
  • Species reactivity
    N/A; Due to limited knowledge and inability for testing each and every species, the reactivity of the antibody may extend to other species which are not listed hereby.
  • Specificity and cross reactivity
    Human ApoA-I; Since it is not possible to test each and every species our knowledge on the corss reactivity of the antibodies is limited. This particular antibody might cross react with speacies outside of the listed ones.
  • Purification method
    > 95% as determined by SDS-Page
  • Form Appearance
    Supplied in 50 mM TRIS, 100 mM NaCl, 1% BSA, 0.02% NaN3, pH 7.4
  • Concentration
    N/A
  • Storage and shipping
    For short term storage keep the antibody at +4°C. Variations in the range 1°C to 9°C are tolerable. For extended periods of time aliquote keep the antibody at -20°C. Cycles of freeze/defrost may denaturate the antibodies, thus reducing their activity..
  • Tested applications
    Flow Cytometry (FC)
  • Properties
    If you buy Antibodies supplied by MBS Monoclonals they should be stored frozen at - 24°C for long term storage and for short term at + 5°C. This MBS Monoclonals Fluorescein isothiocyanate (FITC) antibody is currently after some BD antibodies the most commonly used fluorescent dye for FACS. When excited at 488 nanometers, FITC has a green emission that's usually collected at 530 nanometers, the FL1 detector of a FACSCalibur or FACScan. FITC has a high quantum yield (efficiency of energy transfer from absorption to emission fluorescence) and approximately half of the absorbed photons are emitted as fluorescent light. For fluorescent microscopy applications, the 1 FITC is seldom used as it photo bleaches rather quickly though in flow cytometry applications, its photo bleaching effects are not observed due to a very brief interaction at the laser intercept. MBS Monoclonals FITC is highly sensitive to pH extremes.
  • Conjugation
    Anti-FITC Antibody
  • French translation
    anticorps
  • Gene target
    ApoA-I  
  • Gene symbol
    NAXE
  • Short name
    ApoA-I antibody (FITC)
  • Technique
    Antibody, FITC, antibodies against human proteins, antibodies for, Fluorescein
  • Label
    FITC
  • Alternative name
    Anti-ApoA-I antibody (FITC)
  • Alternative technique
    antibodies, fluorescine
Gene info
MeSH Data
  • Name
  • Concept
    Scope note: Test for tissue antigen using either a direct method, by conjugation of antibody with fluorescent dye (FLUORESCENT ANTIBODY TECHNIQUE, DIRECT) or an indirect method, by formation of antigen-antibody complex which is then labeled with fluorescein-conjugated anti-immunoglobulin antibody (FLUORESCENT ANTIBODY TECHNIQUE, INDIRECT). The tissue is then examined by fluorescence microscopy.
  • Tree numbers
    • E01.370.225.500.607.512.240
    • E01.370.225.750.551.512.240
    • E05.200.500.607.512.240
    • E05.200.750.551.512.240
    • E05.478.583.375
  • Qualifiers
    ethics, trends, veterinary, history, classification, economics, instrumentation, methods, standards, statistics & numerical data
Similar products
Filters
Contact
Chat with gentaur.com employee