IgG1 antibody unlabeled - Negative Control

  • Catalog number
    0G11
  • Price
    Please ask
  • Size
    100 μg
  • Category
    Negative Control
  • Long description
    This monoclonal antibody to IgG1 is a negative control for Immunofluorescence staining with Pure, FITC, Biotin, PE and APC mouse monoclonal antibodies of the IgG1 subclass. It is used to monitor the level of non-specific binding of mouse monoclonal antibodies to human cell surface antigens.
  • Antibody come from
    n/a
  • Other description
    Provided as sterile filtered solution in phosphate buffered saline with 0.08% sodium azide and 0.2% carrier protein. Protein A/G Chromatography
  • Clone
    ZX3
  • Antigen antibody binding interaction
    Mouse IgG1 antibody unlabeled - Negative Control
  • Antibody is raised in
    Mouse
  • Antibody s reacts with
    see techfile
  • Antibody s reacts with these species
    This antibody doesn't cross react with other species
  • Antibody s specificity
    No Data Available
  • Application
    Flow Cytometry
  • Antibody s suited for
    Consult the appropriate fact sheet to determine the amount of antibodies to be used as a control for PBMC or Whole Blood. PBMC: Add 10 µl of MAB/10^6 PBMC in100 µl PBS. Mix gently and incubate for 15 minutes at 2¼ to 8¼C. Wash twice with PBS and analyze. WHOLE BLOOD: Add10 µl of MAB/100 µl of Whole Blood. Mix gently and incubate for 15 minutes at room temperature 20¼C. Lyse the whole blood. Wash once with PBS and analyze. See instrument manufacturerÕs instructions for Lysed Whole Blood and Immunofluorescence analysis with a flow cytometer or microscope. ALLOPHYCOCYANIN: (APC) conjugates are analyzed in multi-color flow cytometry with instruments equipped with a second laser and proper filters. Laser excitation is at 633 nm with a Helium Neon (HeNe) laser or a 600-640 nm (633nm) range for a Dye laser. Peak fluorescence emission is at 660 nm. RPE-Cy-5 +: Excites at 488nm and emits at 670nm. Store protected from light. Optimal concentration should be evaluated by serial dilutions.
  • Storage
    -20ºC
  • Relevant references
    1. Immunofluorescence Measurement in a Flow Cytometer using Low-Power Helium Neon Laser Excitation. Shapiro, H.M, Glazer, A.N., Christenson, L., Williams, J.M., and Strom, T. B. Cytometry 4,276, 1983. _x000B__x000B_2. Comparison of Helium Neon and Dye lasers for Excitation of Allophycocyanin. Loken, M.R., Kiej, J.F. and Kelly, K.,A. Cytometry 8, 96, 1987. _x000B__x000B_Cy-5 + Portions of this product is manufactured under license from Carnegie Mellon University, U.S. Patent Number 5,268,486.
  • Protein number
    see ncbi
  • Warnings
    This product is intended FOR RESEARCH USE ONLY, and FOR TESTS IN VITRO, not for use in diagnostic or therapeutic procedures involving humans or animals. This datasheet is as accurate as reasonably achievable, but Nordic-MUbio accepts no liability for any inaccuracies or omissions in this information.
  • Properties
    If you buy Antibodies supplied by nordc they should be stored frozen at - 24°C for long term storage and for short term at + 5°C.
  • Description
    Isotype or positive controls by peptides, antibodies and deactivated samples. Negative control peptides or isotypes available of the different species.
  • French translation
    anticorps
  • Gene target
    IgG1   unlabeled  
  • Short name
    IgG1 antibody unlabeled - Negative Control
  • Technique
    Antibody, Negative, Control, antibodies against human proteins, antibodies for, controls, negatif
  • Isotype
    IgG1, IgG1
  • Label
    unlabeled
  • Alternative name
    IgG1 (antibody to-) unlabeled - Negative reference
  • Alternative technique
    controls, antibodies
  • Tissue
    control
MeSH Data
  • Name
  • Concept
    Scope note: The technique of washing tissue specimens with a concentrated solution of a heavy metal salt and letting it dry. The specimen will be covered with a very thin layer of the metal salt, being excluded in areas where an adsorbed macromolecule is present. The macromolecules allow electrons from the beam of an electron microscope to pass much more readily than the heavy metal; thus, a reversed or negative image of the molecule is created.
  • Tree numbers
    • E01.370.225.500.620.670.520
    • E01.370.225.750.600.670.520
    • E05.200.500.620.670.520
    • E05.200.750.600.670.520
  • Qualifiers
    ethics, trends, veterinary, history, classification, economics, instrumentation, methods, standards, statistics & numerical data
Similar products
Filters
Contact
Chat with gentaur.com employee