ELISA s application
For quantitative measurement of human Fibronectin in cell culture supernatant, serum and plasma heparin, EDTA, citrate .
-
Gene tested
Human Fibronectin
-
ELISA standard curve
Concentration(pg/ml) + 0 + 156 + 312 + 625 + 1250 + 2500 + 5000 + 10000 O.D. + 0.037 + 0.108 + 0.190 + 0.328 + 0.527 + 1.003 + 1.418 + 1.983
-
ELISA kit detection limits
156pg/ml to 10000g/ml
-
ELISA s sensitivity
< 10pg/ml
-
Target of this ELISA
Natural human Fibronectin
-
Cross reaction
the ELISA does not cross react with any other proteins except from closely related species
-
ELISA s precision parameters
intra assay precisions and inter assay precisions samples;1;2;3;1;2;3 n;16;16;16;24;24;24 mean (ng/ml);1.23;2.35;5.53;1.54;2.39;5.78 ELISA standard deviations 0.063;0.099;0.265;0.120;0.177;0.399 CV(%);5.1;4.2;4.8;7.8;7.4;6.9
-
ELISA kit description
GENTAUR's human Fibronectin ELISA Kit was based on standard sandwich enzyme-linked immune-sorbent assay technology. A polyclonal antibodies from rabbit specific for Fibronectin was used as capure antibodies on the ELISA test plate. The internal standards (from plasma) and your samples are measured with a biotin conjugated polyclonal from goat specific for Fibronectin will than be washed with PBS. The colour reaction with TMB on HRP will colour the well from blue to yellow with the stop solution. The more human Fibronectin in your sample the higher the ELISA signal will be compared to this elisa's standard curve.
-
Detector and capure antibodies
a polyclonal antibodies from rabbit;a biotinylated polyclonal antibodies from goat
-
The ELISA contains
Catalog number;Description;Quantity -;96-well plate precoated with anti- human Fibronectin antibodies;1 ST0000-10;Lyophilized human Fibronectin standard;10ng/tube×2 AR1107;Biotinylated anti- human Fibronectin antibodies;130μl(dilutions 1:100) AR1103;Avidin-Biotin-Peroxidase Complex (ABC);130μl(dilutions 1:100) AR1106-1;Sample diluent buffers;30 ml AR1106-2;antibodies diluent buffers;12ml AR1106-3;ABC diluent buffers;12ml AR1104;TMB color developing agents;10ml AR1105;TMB stop solution;10ml -;Adhesive cover;4
-
Anti coagulation
heparin, EDTA or citrate
-
How the elisa works
Sample the amount of 100ul/well of the standard solution at 10000pg/ml, 5000pg/ml, 2500pg/ml, 1250pg/ml, 625pg/ml, 312pg/ml, 156pg/ml human Fibronectin standard solutions into the precoated 96-well plate. Add 0.1ml of the sample diluent buffers into the control well (Zero well). Add 0.1ml of each properly diluted sample of human cell culture supernatant, serum or plasma(heparin, EDTA, citrate) to the ELISA plate. Keep in mind that each human Fibronectin standard solution and each sample be measured in duplicate.
-
Minutes of TMB incubation
25-30
-
More gene info
Fibronectin(FN) also known as LETS, is identified on the surfFN of fibroblasts by labeling with radioactive compounds or specific antibodies. Fibronectin is a 430,000-dalton dimeric glycoprotein that exists in 2 forms, termed cellular and plasma fibronectin. Cellular and plasma fibronectins are heterodimers consisting of similar but not identical polypeptides. These two forms of FN differ in biologic activity. Fibronectins bind cell surfFNs and various compounds including collagen, fibrin, heparin, DNA, and actin. Because fibronectin stimulates endocytosis in several systems and promotes the clearance of particulate material from the circulation, it could function in the clearance of C1q-coated material such as immune complexes or cellular debris. Fibronectins are involved in cell adhesion, cell motility, opsonization, would healing, and maintenance of cell shape. LETS, encoded on chromosome 8, is responsible for the LETS protein expression in humans. Because LETS has been implicated in tumorigenicity and cellular transformation, it is of interest that rearrangement or modifications in the number of chromosome 8 have been associated with certain forms of cancer. The standard used in this kit is isolated from human plasma with the molecular mass of 200-250KDa.
-
Antigen
from plasma
-
Keep at
Store at 4˚C for 6 months, at -20˚C for 12 months. Avoid multiple freeze-thaw cycles(Shipped with wet ice.)
-
Uniprot
Fibronectin
-
Gene name
fibronectin 1
-
Alternative
CIG;Cold insoluble globulin;Cold-insoluble globulin;Fibronectin 1;FINC;FINC_HUMAN;FN;FN1;FNZ;Migration stimulating factor;MSF;Ugl-Y3
-
Gen protein identity
P02751
-
Entrez nr
2335
-
Properties
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
-
Test
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
-
Gene target
-
Gene symbol
FN1
-
Short name
Fibronectin PicoKine ELISA Kit
-
Technique
ELISA kit, ELISA, ELISAs Enzyme-linked immunosorbent assay 90320007 SNOMED code are used by the medical researcher for detection of human, mouse, … proteins are supplied in coated 96 well plates to be stored at +4°C. ELISA test kits can be sandwich ELISA. In sandwich ELISAS Enzyme-linked immunosorbent assay 9we use captor and detector antibodies. In single antibody ELISAs the antigen is coated and only a detector antibody is used. Traditional competition antigen ELISAs are coated with a captor antibody and a competitive antigen is labelled with the chromogen. In this case the ratio on your graph will be inverse proportional with the antigen present in your sample. A sign detected by the Colorimetric detection OD optical density absorbance at 450 nm between 0 and 4 with an ELISA reader for 450 nm absortion. Genprice Inc. the recognized authority tax ID 45-4304622 D-U-N-S number - 078440800. MeSH code E05 478 566 350 170 Enzyme-Linked Immunosorbent Assay. PROMT code 3841327 Immunoabsorbent assay tests. ELISA tests are enzyme linked immunoassays to detect human, mouse or other proteins in serum, plasma, urine or biological fluids. MeSH code E05 478 566 350 170 for Enzyme-Linked Immunosorbent Assay or ELISA kits. Also Enzyme-linked immunoassay, competitive have the SNOMED name 61461007 and the PROMT code for ELISA readers is 3841330. This is the desigation of other diagnostic analyzers and tests.
-
Host
antigen assay ELISA kit 1 Kit (96 Wells)
-
Species
Human, Humans
-
Alternative name
H. sapiens Fibronectin PicoKine Enzyme-linked immunosorbent assay reagent
-
Alternative technique
elisas, kits
-
Alternative to gene target
v-kit Hardy-Zuckerman 4 feline sarcoma viral oncogene homolog, C-Kit and CD117 and PBT and SCFR, KIT and IDBG-18980 and ENSG00000157404 and 3815, transferase activity, Extracellular, Kit and IDBG-172083 and ENSMUSG00000005672 and 16590, KIT and IDBG-642326 and ENSBTAG00000002699 and 280832
-