Verified reactivity
Homo sapiens (Human)
-
Detection limits
0.156-10 ng/mL
-
Sensitivity limit
0,063 ng/mL
-
Samples to be analyzed
Tissue homogenates, cell lysates and other biological fluids.
-
Assay duration
3 hours
-
Verified applications
ELISA
-
Assay class
Sandwich
-
ELISA detection
Colorimetric
-
Protein number
P01730
-
Alternate protein number
Please refer to SwissProt
-
Gene number
920
-
Gene name
Cluster Of Differentiation 4
-
Alternate gene name
CD4mut; p55; T-cell surface glycoprotein CD4; T-cell surface antigen T4/Leu-3
-
Estimated production time
7-11 business days
-
Shipping requirements
Blue ice
-
Storage recommendation
-20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
Use for
8 months
-
ELISA s specificity
This assay has high sensitivity and excellent specificity for detection of Cluster Of Differentiation 4 (CD4). No significant cross-reactivity or interference between Cluster Of Differentiation 4 (CD4) and analogues was observed.
-
ELISA s cross reactivity
This assay doesn't seem to cross-react with other species. For more information about cross-reactivity please contact us.
-
Assay principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Cluster Of Differentiation 4 (CD4). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Cluster Of Differentiation 4 (CD4). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Cluster Of Differentiation 4 (CD4), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Cluster Of Differentiation 4 (CD4) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
-
Protocol
Please see ELISA's datasheet, otherwise contact us
-
Precision of the test
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cluster Of Differentiation 4 (CD4) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cluster Of Differentiation 4 (CD4) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV
-
ELISA s stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
-
QC
The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
-
Research main area
Signal transduction;CD & Adhesion molecule;Immune molecule;
-
Warnings
The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
Notes
For research use only. Not for diagnostic procedures.
-
-
Description
CD4+ T helper cell marker or cluster differentiator of white blood cells in FACS or flow cytometry. Used offer coupled to magnetic beads. GENTAUR makes custom magnetic bead couplings on 50 and 250 nm beads for certain clones. A microtiter plate (spelled Microtiter is a registered trade name in the United States) or microplate or micro well plate or multiwell, is a flat plate with multiple "wells" used as small test tubes. The microplate has become a standard tool in analytical research and clinical diagnostic testing laboratories. A very common usage is in the enzyme-linked immunosorbent assay (ELISA), the basis of most modern medical diagnostic testing in humans and animals.
A microplate typically has 6, 24, 96, 384 or 1536 sample wells arranged in a 23 rectangular matrix. Some microplates have even been manufactured with 3456 or 9600 wells, and an "array tape" product has been developed that provides a continuous strip of microplates embossed on a flexible plastic tape.
-
Properties
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
-
Test
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
-
Gene target
-
Gene symbol
CD4
-
Short name
Cluster Of Differentiation 4 (CD4) ELISA Kit, 96
-
Technique
ELISA kit, ELISA, ELISAs Enzyme-linked immunosorbent assay 90320007 SNOMED code are used by the medical researcher for detection of human, mouse, … proteins are supplied in coated 96 well plates to be stored at +4°C. ELISA test kits can be sandwich ELISA. In sandwich ELISAS Enzyme-linked immunosorbent assay 9we use captor and detector antibodies. In single antibody ELISAs the antigen is coated and only a detector antibody is used. Traditional competition antigen ELISAs are coated with a captor antibody and a competitive antigen is labelled with the chromogen. In this case the ratio on your graph will be inverse proportional with the antigen present in your sample. A sign detected by the Colorimetric detection OD optical density absorbance at 450 nm between 0 and 4 with an ELISA reader for 450 nm absortion. Genprice Inc. the recognized authority tax ID 45-4304622 D-U-N-S number - 078440800. MeSH code E05 478 566 350 170 Enzyme-Linked Immunosorbent Assay. PROMT code 3841327 Immunoabsorbent assay tests. ELISA tests are enzyme linked immunoassays to detect human, mouse or other proteins in serum, plasma, urine or biological fluids. MeSH code E05 478 566 350 170 for Enzyme-Linked Immunosorbent Assay or ELISA kits. Also Enzyme-linked immunoassay, competitive have the SNOMED name 61461007 and the PROMT code for ELISA readers is 3841330. This is the desigation of other diagnostic analyzers and tests.
-
Host
antigen assay ELISA kit 1 Kit (96 Wells)
-
Species
Human, Humans
-
Alternative name
H. sapiens Cluster on Differentiation 4 (CD4 molecule) Enzyme-linked immunosorbent assay reagent, 96 well plate
-
Alternative technique
elisas, kits
-
Alternative to gene target
CD4 molecule, CD4mut, CD4 and IDBG-15034 and ENSG00000010610 and 920, protein homodimerization activity, Cell surfaces, Cd4 and IDBG-188351 and ENSMUSG00000023274 and 12504, CD4 and IDBG-640247 and ENSBTAG00000003255 and 407098
-