COMBI Surface: IgG2a Negative Control (FITC) and IgG1 Negative Control (PE)

  • Catalog number
    GCT-202
  • Price
    Please ask
  • Size
    50 Tests
  • Category
    Negative Control
  • Long description
    Each staining performed with specific monoclonal antibodies should be paralleled by a staining with an appropriate istotype matched control antibody, in order to be able to control for non-specific binding. The COMBI-REAGENT-Negative Control permits to estimate the degree of non-specific binding of isotype matched immunologbulins to leukocytes via e.g. Fc-receptors. It enables the expert to set flow cytometric parameters accordingly. Results must be put within the context of other diagnostic tests as well as the clinical history of the patient by a certified professional before final interpretation. Analyses performed with this antibody should be paralleled by positive and negative controls. If unexpected results are obtained, which cannot be attributed to differences in laboratory procedures, please contact us.
  • Antibody come from
    n/a
  • Other description
    PBS pH 7.2, 1% BSA, 0.05% NaN3
  • Clone
    4H1-A7 and VI-AP
  • Antigen antibody binding interaction
    see techfile COMBI Surface: IgG2a Negative Control (FITC) and IgG1 Negative Control (PE)
  • Antibody is raised in
    see techfile
  • Antibody s reacts with
    Mouse
  • Antibody s reacts with these species
    This antibody doesn't cross react with other species
  • Antibody s specificity
    The monoclonal antibodies have no known specificity for human leukocytes. It is recommended to use similar amounts of test antibody and isotype matched COMBI-REAGENT Negative Control antibody in each experiment.
  • Research interest
    CD Marker
  • Application
    Direct Immunofluorescence
  • Antibody s suited for
    Direct Immunofluorescence (Staining Procedure) Nordic-MUbio fluorochrome labeled antibodies are designed for use with either whole blood or isolated mononuclear cell (MNC) preparations. Proposed staining procedure for whole blood in short: - For each sample add 50 µl of EDTA anti-coagulated blood to a 3-5 ml tube - Add 20 µl of the appropriate Nordic-MUbio monoclonal antibody conjugate - Incubate the tube for 15 minutes at 4°C or at room temperature in the dark - Add 100 µl NM-LYSE (Cat.No. GAS-003) to each tube and incubate for 10 minutes at room temperature - Add 3-4 ml of destilled water and vortex, incubate for 5-10 minutes at room temperature - Centrifuge tube for 5 minutes at 300 g - Aspirate supernatant and resuspend pellet in 0.3 ml of sheath fluid - Analyze immediately or store samples at 2-8° C in the dark and analyze within 24 hours For “No-Wash” protocol please refer to www.nordicmubio.com Proposed staining procedure for MNC in short: - Carefully add 20 µl antibody conjugate and 50-100 µl MNC to the bottom of a tube - Vortex at low speed for 1-2 seconds - Incubate for 15-30 minutes at 2-8°C or at room temperature - Centrifuge tubes for 5 minutes at 300 g - Remove supernatant, resuspend cells in 2-5 ml of phosphate buffered saline (PBS) and centrifuge cells again for 5 minutes at 300 g - Remove supernatant and resuspend cells in sheath fluid for immediate analysis or resuspend cells in 0.5 ml 1 % formaldehyde and store them at 2-8°C in the dark. Analyze fixed cells within 24 hours
  • Storage
    Nordic-MUbio monoclonal antibody reagents contain optimal concentrations of affinity-purified antibody. For stability reasons this monoclonal antibody solution contains sodium azide. These reagents should be stored at 2-8°C (DO NOT FREEZE!) and protected from prolonged exposure to light. Stability of the reagent: Please refer to the expiry date printed onto the vial. The use of the reagent after the expiration date is not recommended.
  • Relevant references
    no information yet
  • Protein number
    see ncbi
  • Warnings
    For professional users only. This reagent contains sodium azide. To avoid the development of hazardous conditions, reagents containing azide should be diluted in running water prior to be discarded. Similar to the work with other biological products, proper handling procedures are recommended.
  • Description
    Isotype or positive controls by peptides, antibodies and deactivated samples. Negative control peptides or isotypes available of the different species.
  • Properties
    This nordc Fluorescein isothiocyanate (FITC) antibody is currently after some BD antibodies the most commonly used fluorescent dye for FACS. When excited at 488 nanometers, FITC has a green emission that's usually collected at 530 nanometers, the FL1 detector of a FACSCalibur or FACScan. FITC has a high quantum yield (efficiency of energy transfer from absorption to emission fluorescence) and approximately half of the absorbed photons are emitted as fluorescent light. For fluorescent microscopy applications, the 1 FITC is seldom used as it photo bleaches rather quickly though in flow cytometry applications, its photo bleaching effects are not observed due to a very brief interaction at the laser intercept. nordc FITC is highly sensitive to pH extremes.
  • Conjugation
    Anti-FITC Antibody
  • Gene target
    COMBI   Surface   IgG2a   IgG1  
  • Short name
    COMBI Surface: IgG2a Negative Control (FITC) IgG1 Negative Control (PE)
  • Technique
    Negative, Control, FITC, controls, Fluorescein, negatif
  • Isotype
    IgG2a and IgG1, IgG1, IgG2a
  • Label
    FITC and PE
  • Alternative name
    COMBI Surface: IgG2a Negative reference (fluorecein) and IgG1 Negative reference (peroxidase)
  • Alternative technique
    controls, fluorescine
  • Tissue
    control
MeSH Data
  • Name
  • Concept
    Scope note: The technique of washing tissue specimens with a concentrated solution of a heavy metal salt and letting it dry. The specimen will be covered with a very thin layer of the metal salt, being excluded in areas where an adsorbed macromolecule is present. The macromolecules allow electrons from the beam of an electron microscope to pass much more readily than the heavy metal; thus, a reversed or negative image of the molecule is created.
  • Tree numbers
    • E01.370.225.500.620.670.520
    • E01.370.225.750.600.670.520
    • E05.200.500.620.670.520
    • E05.200.750.600.670.520
  • Qualifiers
    ethics, trends, veterinary, history, classification, economics, instrumentation, methods, standards, statistics & numerical data