Human Cluster Of Differentiation 4 (CD4) ELISA Kit

  • Catalog number
    EKU03238
  • Price
    Please ask
  • Size
    96 Tests
  • Estimated Turnaround Time
    6-11 Business days
  • Target Name
    Cluster Of Differentiation 4
  • Target s alterntive name
    CD4mut, p55, T-cell surface glycoprotein CD4, T-cell surface antigen T4/Leu-3
  • Species Reactivity
    Homo sapiens (Human)
  • Sample Type
    Tissue homogenates, Cell lysates, Cell culture supernates and other biological fluids
  • Detection Range
    0.156-10 ng/mL
  • Sensitivity
    0.064 ng/mL
  • Precision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cluster Of Differentiation 4 were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cluster Of Differentiation 4 were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
  • Detection Method
    Colorimetric
  • Assay Time
    3 hours
  • Application
    For research use only. Not for diagnostic procedures.
  • Assay Type
    Double-antibody Sandwich
  • Shipping Conditions
    Ice packs
  • Storage Temperature
    Short term: 4°C; Long term: see manual.
  • Precaution of Use
    The Stop Solution is acidic. Do not allow to contact skin or eyes.
  • Shelf life
    Use Human Cluster Of Differentiation 4 (CD4) ELISA Kit before 8 months
  • Specificity
    This assay has high sensitivity and excellent specificity for detection of Cluster Of Differentiation 4
  • Cross Activity
    No significant cross-reactivity or interference between Cluster Of Differentiation 4 and analogues was observed.
  • Test Principle
    No significant cross-reactivity or interference between Cluster Of Differentiation 4 and analogues was observed.
  • Stability
    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
  • Quality Systems
    The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
  • Research Area
    Signal transduction, CD & Adhesion molecule, Immune molecule
  • Description
    CD4+ T helper cell marker or cluster differentiator of white blood cells in FACS or flow cytometry. Used offer coupled to magnetic beads. GENTAUR makes custom magnetic bead couplings on 50 and 250 nm beads for certain clones.
  • Properties
    E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays, Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
  • Test
    ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
  • Gene target
  • Gene symbol
    CD4
  • Short name
    Cluster Of Differentiation 4 (CD4) ELISA Kit
  • Technique
    ELISA kit, ELISA, ELISAs Enzyme-linked immunosorbent assay 90320007 SNOMED code are used by the medical researcher for detection of human, mouse, … proteins are supplied in coated 96 well plates to be stored at +4°C. ELISA test kits can be sandwich ELISA. In sandwich ELISAS Enzyme-linked immunosorbent assay 9we use captor and detector antibodies. In single antibody ELISAs the antigen is coated and only a detector antibody is used. Traditional competition antigen ELISAs are coated with a captor antibody and a competitive antigen is labelled with the chromogen. In this case the ratio on your graph will be inverse proportional with the antigen present in your sample. A sign detected by the Colorimetric detection OD optical density absorbance at 450 nm between 0 and 4 with an ELISA reader for 450 nm absortion. Genprice Inc. the recognized authority tax ID 45-4304622 D-U-N-S number - 078440800. MeSH code E05 478 566 350 170 Enzyme-Linked Immunosorbent Assay. PROMT code 3841327 Immunoabsorbent assay tests. ELISA tests are enzyme linked immunoassays to detect human, mouse or other proteins in serum, plasma, urine or biological fluids. MeSH code E05 478 566 350 170 for Enzyme-Linked Immunosorbent Assay or ELISA kits. Also Enzyme-linked immunoassay, competitive have the SNOMED name 61461007 and the PROMT code for ELISA readers is 3841330. This is the desigation of other diagnostic analyzers and tests.
  • Host
    antigen assay ELISA kit 1 Kit (96 Wells)
  • Species
    Human, Humans
  • Alternative name
    H. sapiens Cluster on Differentiation 4 (CD4 molecule) Enzyme-linked immunosorbent assay reagent
  • Alternative technique
    elisas, kits
  • Alternative to gene target
    CD4 molecule, CD4mut, CD4 and IDBG-15034 and ENSG00000010610 and 920, protein homodimerization activity, Cell surfaces, Cd4 and IDBG-188351 and ENSMUSG00000023274 and 12504, CD4 and IDBG-640247 and ENSBTAG00000003255 and 407098
Gene info
  • Identity
  • Gene
    CD4
  • Long gene name
    CD4 molecule
  • Synonyms gene name
    • CD4 antigen (p55)
    • T-cell surface glycoprotein CD4
  • GenBank acession
  • Locus
  • Discovery year
    1986-01-01
  • Entrez gene record
    920
  • RefSeq identity
  • Classification
    • CD molecules
    • C2-set domain containing
    • V-set domain containing
  • VEGA ID
MeSH Data
  • Name
  • Concept
    Scope note: An immunoassay utilizing an antibody labeled with an enzyme marker such as horseradish peroxidase. While either the enzyme or the antibody is bound to an immunosorbent substrate, they both retain their biologic activity; the change in enzyme activity as a result of the enzyme-antibody-antigen reaction is proportional to the concentration of the antigen and can be measured spectrophotometrically or with the naked eye. Many variations of the method have been developed.
  • Tree numbers
    • E05.478.566.350.170
    • E05.478.566.380.360
    • E05.478.583.400.170
    • E05.601.470.350.170
    • E05.601.470.380.360
  • Qualifiers
    ethics, mortality, psychology, trends, veterinary, history, classification, economics, instrumentation, methods, nursing, standards, adverse effects, statistics & numerical data
Product images
Similar products
Filters
Contact
Chat with gentaur.com employee