European Pharmacopoeia Reagent Coloration - Primary solution Red

  • Catalog number
    EPRS01
  • Price
    Please ask
  • Size
    100ml
  • Diagnostic or laboratory reagents
    3822 0000
  • Substance expires after days
    730
  • Use of chemical
    Pharmacopoeias
  • Application
    European Pharmacopoeia
  • Substance specification
    Chapter 2 - Colour Primary Solution
  • Handling advice
    hazardous
  • UN Nr
    1760
  • ADE CLASS PG TUNNEL
    III 8 E
  • GHS Signal
    Danger
  • ADR explanation
    CORROSIVE LIQUID, N.O.S. (HYDROCHLORIC ACID), ENVIRONMENTALLY HAZARDOUS
  • Awareness
    3.1.O/4 Harmful if swallowed.3.4.R/1 May cause allergy or asthma symptoms or breathing difficulties if inhaled.3.4.S/1 May cause an allergic skin reaction.3.5/2 Suspected of causing genetic defects.3.6/1B May cause cancer.3.7/1B May damage fertility or the unborn child.4.1.A/1 Very toxic to aquatic life.4.1.C/1 Very toxic to aquatic life with long lasting effects.
  • Precautions
    3.2, 2 Causes skin irritation.3.3, 2A Causes serious eye irritation.P280 Wear protective gloves, protective clothing, eye protection, face protection.P264 Wash thoroughly after handling.P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.P321 Specific treatment (see on this label).P332+P313 If skin irritation occurs: Get medical advice, attention.P337+P313 If eye irritation persists: Get medical advice, attention.P302+P352a IF ON SKIN: Wash with plenty of water.P362+P364 Take off contaminated clothing and wash it before reuse.
  • Conjugation
    red dye
  • Description
    The volume (ml) in milliliters of buffered % w/v solutions at the medium pH are also used for DNA extraction Organic (Phenol-Chloroform) Extraction, Non-Organic (Proteinase K and Salting out), Chelex (Ion Exchange Resin) Extraction, EDTA or PBS aqueous.
MeSH Data
  • Name
  • Concept
    Scope note: Immunologic techniques based on the use of: (1) enzyme-antibody conjugates; (2) enzyme-antigen conjugates; (3) antienzyme antibody followed by its homologous enzyme; or (4) enzyme-antienzyme complexes. These are used histologically for visualizing or labeling tissue specimens.
  • Tree numbers
    • E05.478.566.350
    • E05.478.583.400
    • E05.601.470.350
  • Qualifiers
    ethics, trends, veterinary, history, classification, economics, instrumentation, methods, standards, statistics & numerical data